HTS

Stand for HT420 Thermal Tweezers

INSTRUCTION MANUAL

Summary of Contents for HT-SF

Page 1: ...HTS Stand for HT420 Thermal Tweezers INSTRUCTION MANUAL ...

Page 2: ...0 Thermal Tweezers 1 unit The following items are included This manual corresponds to the following reference HT SF Packing List Stand Cable 1m 1 unit Ref 0024227 Sponge for Modular Tool Stands 1 unit Ref S7034 Brass Wool 1 unit Ref CL6210 2 ...

Page 3: ...es color gris 200 mm Features and Connections Control Unit not included sold separately To Tool Quick Tip Changer Ajustable Tool Holder Brass Wool inside Wiper for Modular Tool Stand Ref CL7899 Adjustable Cable Collector Ref CC1001 Cartridge Storage Sponge 3 ...

Page 4: ... wiper offers different ways to clean the cartridge tips If desired use the included sponge Insert the cable into the cable collector clip Do not leave the cable longer than necessary to reach the work area freely The cable collector is flexible It accompanies and adapts to the movements during the soldering process 4 ...

Page 5: ...ll the tweezers to remove the cartridges Unlock the cartidge fixing screws 3 Inserting 4 Locking Use the grooves to insert the cartridges as far as the mark Lock the fixing screws Important It is essential to insert the cartridges as far as the mark for a proper connection Mark Quick Tip Changer For a safe cartridge exchange unplug the tool or turn the station off srews srews 5 ...

Page 6: ...ng to avoid tip wear The integrated wiper offers different ways to clean the cartridge tips Wiper and Brass Wool Replacement Lift the wiper at its front edge The wiper and brass wool can easily be removed for cleaning or replacement when they are worn Remove the wiper by pulling it out Replace the brass wool with a new one when it is worn out Place the wiper back o replace them if desired 6 ...

Page 7: ...tand from the station and the tool Use a damp cloth to clean the stand Alco hol can be used only when cleaning the metal parts Check periodically that the metal parts of the tool stand are clean so that the station can check the tool s status Periodically check all cables and tube connections Replace any defective or damaged parts Use original JBC spare parts only Repairs should only be performed ...

Page 8: ...at can cause inflamable products to ignite Avoid the contact of flux with skin or eyes to prevent irritation Be careful with the fumes produced when soldering Keep your workplace clean and tidy Wear appropriate protection glasses and gloves when working to avoid personal harm Utmost care must be taken with liquid tin waste which can cause burns This appliance can be used by children over the age o...

Page 9: ...40 mm 50 mm 60 mm 80 mm 100 mm 130 mm 130 mm para manuales color gris 200 mm Notes 9 ...

Page 10: ...Notes 10 ...

Page 11: ...40 mm 50 mm 60 mm 80 mm 100 mm 130 mm 130 mm para manuales color gris 200 mm Notes 11 ...

Page 12: ...ng the replacement of defective parts and labour Warranty does not cover product wear or misuse In order for the warranty to be valid equipment must be returned postage paid to the dealer where it was purchased para manuales color gris 0027182 1121 HTS Stand for HT420 Thermal Tweezers Ref HT SF Includes Sleep Mode Hibernation Mode Total Net Weight 1544 g 3 40 lb Package Dimensions Weight 342 x 155...