JB Platinum Series Operating Instructions & Parts Manual Download Page 1

1

,
,

In order to make the best use of your
investment, familiarize yourself with the
new features and operating instructions
before starting pump. With just routine
care your

Platinum

 will give you years of

reliable service by following proper
maintenance guidelines.

Platinum pumps

are designed for deep vacuum work in
refrigeration systems only.

IMPORTANT:

Use oil specifically refined

for deep vacuum pumps. Using oil not
refined for deep vacuum pumps and/or
operating with contaminated oil will void
warranty.

IMPORTANT

This unit has been drained for shipment.

DO NOT ATTEMPT TO OPERATE

WITHOUT ADDING OIL.

TM

2-Stage, Direct Drive

OPERATING INSTRUCTIONS

,

& PARTS MANUAL

Platinum  Series Vacuum Pumps

DV-42N, DV-85N,
DV-142N, DV-200N & DV-285N

MOTOR

1/2 HP, 50HZ, 230 Volt; Capacitor start;
Automatic thermal overload protected.

INTAKE

DV-42N

1/4 Male Flare

DV-85N

1/4 x 3/8 Male Flare

DV-142N,
DV-200N & DV-285

3/8 x 1/4 x 3/8 Male Flare

FREE AIR DISPLACEMENT

CFM

Liters Per Minute

DV-42N

1.5

42

DV-85N

3

85

DV-142N

5

142

DV-200N

7

200

DV-285N

10

285

-250 Series

MOTOR

1/2 HP, 50 HZ, 230 Volt; Capacitor start;

protected.

INTAKE PORT

See Above

FREE AIR DISPLACEMENT

50 HZ

Liters Per

CFM

Minute

DV-42N-250

1.25

35

DV-85N-250

2.5

71

DV-142N-250

4.2

119

DV-200N-250

5.8

167

DV-285N-250

8.3

237

Specifications

¡

Automatic thermal overload

Dual voltage 
motors avail-
able upon 
request

EXHAUST

OIL DRAIN VALVE

Close Drain Finger

Tight.

OIL FILL PLUG

Do Not Wrench
Down Or Use

Sealant On

Threads

GAS BALLAST

VALVE

INTAKE

ISOLATION

(BLANK-OFF)

VALVE

,

Each

Platinum

pump has been factory tested to guarantee 25 micron or 

better and listed CFM performance. The serial number has been recorded. 
Complete and mail the Warranty Registration Card within10 days of 
purchase to validate your warranty. You will be notified of any technical 
updates.

25,400 Microns = 1"

Summary of Contents for Platinum Series

Page 1: ...ted INTAKE DV 42N 1 4 Male Flare DV 85N 1 4 x 3 8 Male Flare DV 142N DV 200N DV 2853 8 x 1 4 x 3 8 Male Flare FREE AIR DISPLACEMENT CFM Liters Per Minute DV 42N 1 5 42 DV 85N 3 85 DV 142N 5 142 DV 200N 7 200 DV 285N 10 285 250 Series MOTOR 1 2 HP 50 HZ 230 Volt Capacitor start protected INTAKE PORT See Above FREE AIR DISPLACEMENT 50 HZ Liters Per CFM Minute DV 42N 250 1 25 35 DV 85N 250 2 5 71 DV ...

Page 2: ...FORE ADDING OIL The following procedures will prevent oil from being drawn into cartridge and creating hard start up CHANGING OIL To reach deep vacuum Platinum pumps need clean moisture free oil throughout evacuation Care should be taken to avoid contact on skin and clothing when changing oil Used oil should be disposed of in a leakproof corrosive resistant container Pump oil should be changed aft...

Page 3: ...2 PR 4 2 PR 42 PR 208 1 PR 1 Sight Glass 2 PR 2 Drain Valve PR 300 DV 42N through DV 200N Cover Assy 3 w Sight Glass and Drain Valve PR 301 DV 285N Cover Assy w Sight Glass and Drain Valve PR 305 DV 42N Cartridge w O Rings and Cover Seal PR 302 DV 85N Cartridge w O Rings and Cover Seal 4 PR 303 DV 142N Cartridge w O Rings and Cover Seal PR 304 DV 200N Cartridge w O Rings and Cover Seal PR 314 DV 2...

Page 4: ... the repair replacement or credit at invoice price our option of products which in our opinion are defective due to defects in workmanship and or materials In no case will we allow charges for labor expense or consequential damage Repairs performed on items out of warranty will be invoiced on a nominal basis Contact you wholesaler for details TROUBLESHOOTING CHART Thermal overload may be open Pump...

Reviews: