FUNCTIONS (FRONT) 

 

 

 

1.  FIXED COLOR BUTTONS:

 9 buttons each with a preset color. 

2.  MODE SELECT BUTTONS:

 3 buttons used to set the controller in different working modes: 

 FIXED COLORS:

 select this mode if you want to use the “fixed color” buttons (1).

 

 CHASE MODE:

 select this mode if you want to select one of the 12 color chases using the 

“chase/color” fader (3).

 

 SPECTRUM MIX:

 select this mode if you want to select one of the 32 different colors using the 

“chase/color” fader (3).

 

3. CHASE/COLOR 

FADER:

 used to select one of the available color chases:

 

 

Left side of the fader indicates the different chases. 

 

Right side of the fader indicates the different colors. 

Important remark:

 There’s also a function called 

“color fade” 

which is very nice for “background 

lighting” applications. Select this function to fade gently from one color to another. You can adjust 
the fade-over time with the color-fade fader(4).

 

4. SPEED/FADE 

FADER:

 used to select the chase speed or color fade time:

 

 

Left side of the fader indicates the chase speed, ranging from 2,5s to 0,1s. 

 

Right side of the fader indicates the color fade time, ranging from 12s to 2,5s. 

5. MASTER 

FADER:

 used to control the overall dimming of the LEDs and overall strobe speed.

 

6. SOUND 

BUTTON:

 used to toggle the chase mode between sound and static mode.

 

7. FULL 

ON 

BUTTON:

 used to set the 3 colors (R+G+B) at maximum level.

 

8. BLACKOUT 

BUTTON:

 used to set the 3 colors (R+G+B) at zero level.

 

 
 

FUNCTIONS (REAR) 

 

9. POWER 

SWITCH:

 Used to switch the unit ON/OFF 

10. DC INPUT: 

connect the supplied AC/DC adapter to this input. If you should use another adapter, please 

make sure that it has 9Vdc and minimum 300mA with + in the center.  

11. DMX OUTPUT: 

Sends DMX-signals to the connected units. 

 
 

ENGLISH  

OPERATION 

MANUAL 

 

 
JB SYSTEMS® 

4/20 

LEDCON-01 remote 

CONNECTIONS 

With LED MANAGER: 

 You need to “daisy chain” the DMX in/outputs of 1 or more LED-Managers with the DMX-output of the 

LEDCON-01 remote using a good quality balanced cable (ex. JB Systems ref. 7-0063).  

 

 

  The LEDCON-01 remote will be used to control all connected slaves. The LED Managers are automatically 

switched as slaves (slave LED is lit). The controls on the slave units are disabled. 

 
With LED BALL and/or LED SPOT/WASH : 

  You need to “daisy chain” the DMX in/outputs of 1 or more LED BALL and/or LED SPOT/WASH projectors 

with the DMX-output of the LEDCON-01 remote using a good quality balanced cable (ex. JB Systems ref. 
7-0063).  

 

  In order to work perfectly all connected LED projectors must have DMX address 001. To set all projectors 

to DMX address 001, do the following: push the “auto DMX address” button on all projectors. First press 
the button on slave1, than slave2, than3, etc.  

Remark:

 All connected LED projectors will respond equaly (all will have the same colour) If you like, you can 

also put 1 or more LED MANAGER(s) in the DMX-chain. 
 
 

SPECIFICATIONS 

Power Input: 

DC 9V 300mA minimum. 

AC/DC Power adapter:

 

AC 240V, 50Hz 

Æ

 9Vdc / 300mA (or more) 

DMX output: 

3pin XLR  

Audio input:

 None, 

internal 

microphone 

Size:

 

21,0 x 14,0 x 4,6cm  

Weight:

 930 

grams 

 
 

Every information is subject to change without prior notice 

You can download the latest version of this user manual on our website: www.beglec.com 

Summary of Contents for LEDCON-01

Page 1: ...cva Reproduction or publication of the content in any manner without express permission of the publisher is prohibited Version 1 1 Operation Manual Mode d emploi Gebruiksaanwijzing Bedienungsanleitung...

Page 2: ...t toestel en de gebruikte batterijen op een milieuvriendelijke manier conform de in uw land geldende voorschriften DU ENTSORGUNG DES GER TS Entsorgen Sie das Ger t und die Batterien auf umweltfreundli...

Page 3: ...or shock hazard do not expose this appliance to rain or moisture To avoid condensation to be formed inside allow the unit to adapt to the surrounding temperatures when bringing it into a warm room aft...

Page 4: ...ed to switch the unit ON OFF 10 DC INPUT connect the supplied AC DC adapter to this input If you should use another adapter please make sure that it has 9Vdc and minimum 300mA with in the center 11 DM...

Page 5: ...tez quelques minutes pour laisser l appareil s adapter la temp rature ambiante lorsqu il arrive dans une pi ce chauff e apr s le transport La condensation emp che l unit de fonctionner en performance...

Page 6: ...D ALIMENTATION utilis pour allumer ou teindre l appareil ON OFF 10 ENTR E DC branchez l adaptateur AC DC fourni sur cette entr e Si vous devez utiliser un autre adaptateur veuillez vous assurer qu il...

Page 7: ...dit om het risico op brand en elektrische schokken te voorkomen Om de vorming van condensatie binnenin te voorkomen laat het apparaat aan de omgevingstemperatuur wennen wanneer het na het transport na...

Page 8: ...CTIES ACHTERZIJDE 9 POWER SCHAKELAAR wordt gebruikt om de unit aan uit te schakelen 10 DC INGANG sluit de meegeleverde AC DC adapter aan op deze ingang Als u een andere adapter gebruikt weet dan zeker...

Page 9: ...ichtig trennen DEUTSCH BEDIENUNGSANLEITUNG JB SYSTEMS 14 20 LEDCON 01 remote SICHERHEITSHINWEISE Dieses Symbol bedeutet Nur innerhalb von R umen verwenden Zur Vermeidung von Stromschlag oder Feuer Ger...

Page 10: ...DC Netzteil an diesen Eingang an Falls Sie einen anderen Adapter verwenden wollen pr fen Sie bitte ob dieser 9V DC bei mindestens 300 mA mit in der Mitte liefern kann 11 DMX AUSGANG Schickt DMX Signal...

Page 11: ...e s mbolo significa uso para el interior solamente Para evitar riesgos de incendio o electrocuci n no exponer el aparato a la lluvia o a la humedad Para evitar que se forme condensaci n en el interior...

Page 12: ...R G B al m ximo 8 BOT N DE APAGADO usado para establecer los 3 colores R G B a cero FUNCIONES PARTE TRASERA 9 INTERRUPTOR DE ENCENDIDO Usado para encender apagar la unidad 10 ENTRADA CD conecte el ada...

Reviews: