LED FADE OUT - type of dimming

Used to set how to dim the lower range from 0-5%.
STANDARD: When dimming the headlamp, all LED's dim out at the same time.
SOFT: When the headlamp is dimmed, the LED's are dimmed out in groups (in a row) one row 
after the other.

5.6 STANDALONE operation

In standalone operation, up to 20 program steps can be stored in the P18 MK2 Wash, which 
can then run in an endless loop. The images can be saved in two ways. Either you program the 
desired DMX values directly on P18 MK2 Wash and save them, or you set the DMX values via a 
connected DMX console and then store them in the P18 MK2 Wash.
The menu items MODIFY, RUN and REMOTE can only be called up using a specific key 
combination. To do this, press and hold “ENTER”, and also press “ESC”. Before activating these 
menu items, remove all other devices in the DMX line that send DMX, e.g. consoles or other 
spotlights that are not configured as slave devices, as otherwise damage to the DMX drivers 
may occur.

Programming the standalone programme on the spotlight display:

Call up the STANDALONE, EDIT menu item. In the STEP NR+/- menu item, select the desired step 
and you can change it and its channel parameters in the following menu items: In the MODIFY 
menu item, set the desired lighting scene and position and determine the individual sequence 
times of the steps with FADE TIME and NEXT TIME (time for the complete step).
Use INSERT to insert an additional programming step. The DMX values of the previous step are 
copied to the new step.
Use DELETE to delete a step. The display shows STEP NR: 1/X. Use the selection keys to move 
to the desired step.
With RESET STEP you reset one step to its default values (DMX 000). The display shows STEP 
NR: 1/X. Use the selection keys to select your step. CLEAR ALL resets the complete standalone 
programming steps. Under MODIFY you will find STEP1/1 again. In the STANDALONE, TIMEBASE 
menu item you have the possibility to change the Fade Time and Next Time from 1 second to 
1/10 second.

Launch the standalone program:

Call up the STANDALONE menu and navigate to the RUN submenu. Confirm the selection by 
pressing the key combination “ENTER” (press and hold) and simultaneously “ESC”. The display 
then shows: S-ALONE: 01/XX and the program runs in an endless loop. 
Deactivation: Press and hold the “ESC” key and then also press "ENTER". The menu jumps back 
one level and RUN appears in the display.

Accept the DMX values from an external console:

To accept the DMX values of a connected console, you must first enable the Capture DMX input. 
To do this, go to the CAPT DMX menu item. The display now shows CAPTURE DMX 01/01, press 
the Enter key to switch to START CAPTURE. Now the P18 MK2 Wash reacts to the signals from 
the external console.

Summary of Contents for P18 MK2 Wash HP

Page 1: ...Operating instructions Version 1 01 Software 1 1 0 P1 8 mk2 Wash...

Page 2: ...02 P1 8 MK2 Wash...

Page 3: ...ssing 16 5 5 PERSONALITY Personal settings 16 5 6 STANDALONE operation 19 5 7 INFO menu 20 5 8 Shortcuts quick access 20 6 Control options 21 6 1 DMX 21 6 1 1 Operating modes 21 6 1 2 DMX channel assi...

Page 4: ...nlagentechnik GmbH Sallersteig 15 89134 Blaustein 140 140 258 4 307 480 5 475 630 267 541 Name Erstellt Art Nr Datum Prisma Fax 07304 9617 99 Tel 07304 9617 0 P18 Wash 17 01 2018 Kuehngruen Allgemeint...

Page 5: ...m Blechdicke Material Farbe Oberfl che Abmessung Lichtanlagentechnik GmbH Sallersteig 15 89134 Blaustein hdicke Material e rfl che Abmessung 2 Product overview Head Fresnel front lens Tilt lock Arm P...

Page 6: ...n cables as this could result in fire or electric shock Do not place any objects on the power cable Do not install the spotlight in such a way that people can trip over or step on the power cable Make...

Page 7: ...nock the device Avoid brute force during installation or operation This light was designed for indoor use only Do not expose this device to rain or moisture When choosing a mounting location make sure...

Page 8: ...sifthedeviceistobetransported When using the original packaging the locks must not be closed ATTENTION Only have plugs installed by a specialist The P18 MK2 Wash spotlight is supplied with a partially...

Page 9: ...ted or a DMX signal is present Connection outside Europe The P18 MK2 Wash may only be operated on the following power supply systems Mains P18 MK2 Wash 2 wires 1 phase L N L N PE 3 wires 1 phase L N L...

Page 10: ...g 4 4 2 Ethernet cabling Ethernet cabling can be done with standard network lines The sockets on the device are Neutrik etherCON sockets Special cables with etherCON connectors are recommended by Neut...

Page 11: ...d ground because the air inlets in the base must not be covered with anything 140 258 4 140 1 2 4 3 To mount the unit on a trussing system use two of the original JB Lighting omega brackets with origi...

Page 12: ...tter module ENTER calls up a sub menu or confirms an input ESC is used to exit a function or a menu item UP and DOWN are used to navigate within the menu and to enter values Special areas can only be...

Page 13: ...n shows an error in the ERROR LIST is still in it but has already been confirmed or was automatically confirmed Only when the error has been deleted from the ERROR LIST does the P18 MK2 Wash start aga...

Page 14: ...PAN TILT SPEED MEDIUM WHISPER SILENT FAST EFFECT SPEED MEDIUM WHISPER SILENT FAST BACKLIGHT MODE OFF ON STANDARD DISPLAY ORIENTA FLIP ON SAFE MODE SWIT OFF ID USER FIXTURE ID STANDARD LED FADE OUT SO...

Page 15: ...DALONE EDIT STEP NR RUN TIMEBASE 1 SEC 1 10 SEC MODIFY REMOTE CAPT DMX INSERT DELETE RESET STEP CLEAR ALL FADE TIME FADE TIME NEXT TIME NEXT TIME PAN PAN TILT TILT CONTROL CONTROL SHUTTER SHUTTER DIMM...

Page 16: ...N buttons The Artnet address is displayed in the form 000 00 00 This display corresponds to Net Subnet Universum The sACN address can then be selected in the DMX NET ADDR sACN ADDRESS menu The address...

Page 17: ...is mode the spot light runs at the same brightness up to an ambient temperature of 40 C It is not necessary to speed up the fans in this mode THEATRE SILENT Brightness 33 500lm model HP from 40 C ambi...

Page 18: ...r changes are possible BACKLIGHT MODE setting the display backlight This menu item controls the backlight of the display OFF The backlight of the display is always off The lighting only switches on wh...

Page 19: ...scene and position and determine the individual sequence times of the steps with FADE TIME and NEXT TIME time for the complete step Use INSERT to insert an additional programming step The DMX values...

Page 20: ...less important source of internal information Under the menu item TOT OPERATE TIME the complete operating time of the headlight is displayed The menu item TOT LAMP TIME provides information about the...

Page 21: ...el 17 Aperture 2a Gobo 1 Channel 18 Aperture 2b Gobo rotation 1 Channel 19 Aperture 3a Gobo rotation 1 fine Channel 20 Aperture 3b Aperture 1a Channel 21 Aperture 4a Aperture 1a fine Channel 22 Apertu...

Page 22: ...hannel 44 Yellow Channel 45 Fine yellow Channel 46 CTO CTB model WW Channel 47 CTO fine CTB fine model WW Channel 48 Sparkle Channel 49 Sparkle speed Channel 50 Frost 1 Channel 51 Frost 2 Channel 52 P...

Page 23: ...low not used Setting for minimum medium DMX smoothing Dimmer fade out via fader fast slow not used Setting for medium DMX smoothing Dimmer fade out via fader fast slow not used Setting for medium maxi...

Page 24: ...ODE selection of dimming out STANDARD SOFT not used COOLING MODE Adjust the fan volume and brightness This takes place with dimmer shutter set to closed DMX 000 then after 2 seconds the fixture will s...

Page 25: ...d slow Shutter open 000 015 016 095 096 110 111 111 112 125 126 126 127 126 128 142 143 143 144 158 159 159 160 174 175 175 176 190 191 191 192 206 207 207 208 222 223 223 224 238 239 239 240 254 255...

Page 26: ...3 224 255 14 18 Gobo positioning rotation 1 Gobo positioning 0 540 Gobo rotation right rapid slow Stop gobo rotation Gobo rotation left slow rapid 000 191 192 222 223 224 225 255 19 Fine gobo position...

Page 27: ...ink model HC and WW HCRI Pink model HC and WW HCRI Pink model HC and WW White Linear colours White Red Yellow Magenta Green Orange Dark Blue HCRI Pink model HC and WW White Colour cycle right rapid sl...

Page 28: ...ng and switching blocks 000 031 032 063 064 255 30 47 Frost 1 Frost 0 100 000 255 31 48 Frost 2 Frost 0 100 000 255 32 49 Pan tilt speed Real time motion Delayed motion rapid slow 000 003 004 255 33 5...

Page 29: ...entire zoom range from software version 1 5 6 1 5 Zoom auto focus distance auto focus balancing 6 2 Artnet The spotlight can be controlled via Artnet ArtNET 4 To do this set the Artnet address via th...

Page 30: ...of the respective desk manufacturer must also be observed Every P18 MK2 Wash has a factory set RDM UID unique identification number which makes it addressable and identifiable in RDM systems 6 5 1 RD...

Page 31: ...k On Off Dimmer Curve RGB Curve Frost Curve Camera Mode Cooling Mode Pan Tilt Speed Effect Speed Backlight Mode Disp Orientation Main Screen Mode Safe Mode Switch LED Fade Out Mode 6 5 4 Manufacturer...

Page 32: ...e function keys to select the DMX channel to be tested The display shows the incoming value at the same time the P18 MK2 Wash reacts accordingly INIT PAN TILT The P18 MK2 Wash is calibrated in the pan...

Page 33: ...a turn lift off the cover and unhook the safety lanyard Now open the two knurled screws 5 and remove the gobo insert The following figure 1 shows the gobo insert of the P18 MK2 Wash To change the gobo...

Page 34: ...er In addition you can remove the gobo insert 1 and the shutter slide insert 2 by loosening the knurled screws 3 and sliding the focus carriage towards the lens Then you can clean the colour filters g...

Page 35: ...ections The fixing screw of the DMX 5 pin socket can be used as measuring point for insulation and residual current measurement The screw is connected to all sheet metal parts via a contact washer 7 5...

Page 36: ...odule 1100W Luminous intensity HP 40000 Lumen 20 C Luminous intensity HC 31000 Lumen 20 C Luminous intensity WW 28000 Lumen 20 C Effects Pan 546 74 Tilt 281 16 Zoom 13 65 Construction Colour black Hou...

Page 37: ...ring methods Limit value class A Radiation Information technology equipment radio interference characteristics EN 55022 2010 Limit values and measuring methods Limit value class A Harmonic currents El...

Page 38: ...38 P1 8 MK2 Wash...

Page 39: ...39 P1 8 MK2 WasH...

Page 40: ...JB Lighting Lichtanlagentechnik GmbH Sallersteig 15 89134 Blaustein Tel 49 7304 9617 0 Fax 49 7304 9617 99 info jb lighting de www jb lighting de...

Reviews: