Section 6: Electrical System
30 AMP Power Cord (if so equipped)
The 30 amp external utility power cord is commonly referred to as the “shore” power cord. It
is designed to mate and properly function with 30 amp “shore” power receptacles available
at most campgrounds.
The shore power cord is designed to continuously carry the 30 amp current flow required to
power each leg of the electrical system. It also creates a critical ground connection between
the vehicle electrical system and the campground shore power receptacle.
Always test the external power source (i.e., the campsite power receptacle or electrical box)
with a ground monitor before connecting your power cord to it. If the ground monitor indi-
cates ‘reverse polarity’ or an ‘open ground’
DO NOT
connect the power cord.
Regularly inspect the shore power cord for cuts, cracks, worn insulation and other damage.
Have the power cord replaced immediately if problems exist.
Calculating 30 AMP Electrical Load (if so equipped)
When connecting appliances to the electrical system, 120-volt power usage is limited to a
total of 30 amps. Operating appliances collectively places an added load on your 120-volt
electrical system.
A circuit breaker “trip” may occur if you overload the recreation vehicle and/or campground
electrical system. The amperage rating of individual appliances can be calculated by divid-
ing appliance wattage consumed (normally listed on the appliance) by nominal design volt-
age (120 for a 120-volt appliance). For example: 1200 watts divided by 120-volts equals
10 amps.
Do not hook up the power cord to any receptacle
until
you have verified
proper polarity and grounding. Polarity indicators can be purchased in
most electrical and hardware stores.
Do not use any cheater plug, adapter or extension cord to reconfigure
incoming AC power or break the continuity of the circuit connected to
the grounding pin.
Do not connect the power cord into an outlet that is not grounded, or
adapt the power cord plug to connect it to a receptacle for which it is not
designed.
Do not remove the grounding pin to connect to a non-grounded recep-
tacle. Removal of the ground pin disables an important safety feature
designed to prevent shock and electrocution hazards.
Do not connect the power cord to an extension cord. Use of an improper
extension cord will cause overheating of the cord as well as potentially
causing premature failure of the AC equipment.
It is the responsibility of the owner of the electrical receptacle to ensure that the
receptacle is properly wired and grounded. Reverse polarity and/or improper
grounding of your recreation vehicle can cause personal injury or death.
Table of Contents
Maintenance Record
Summary of Contents for JAY FEATHER Towables 2021
Page 1: ...Owner s Manual 0195624 2021 2021 Towables A subsidiary of Thor Industries Inc ...
Page 2: ......
Page 10: ...8 Table of Contents Maintenance Record ...
Page 24: ...22 Section 1 Warranty Service Notes Table of Contents Maintenance Record ...
Page 34: ...32 Section 2 Occupant Safety Notes Table of Contents Maintenance Record ...
Page 104: ...102 Section 6 Electrical System Notes Table of Contents Maintenance Record ...
Page 114: ...112 Section 7 Fuel Propane System Notes Table of Contents Maintenance Record ...
Page 136: ...134 Section 8 Plumbing System Notes Table of Contents Maintenance Record ...
Page 150: ...148 Section 11 Electronics Notes Table of Contents Maintenance Record ...
Page 162: ...160 Section 12 Interior Notes Table of Contents Maintenance Record ...
Page 172: ...170 Section 14 Travel Camping Storage Checklists Notes Table of Contents Maintenance Record ...
Page 177: ...175 Section 15 Additional Information Notes Table of Contents Maintenance Record ...