67
Section 6: Electrical System
Starting the Generator
Your motorhome has manual switches located at the Command Center panel. There are sec-
ondary switches located on the dash, in an overhead cabinet, or on the generator itself. An
hour meter that keeps track of generator hours used is located near the switch and a separate
hour meter on the generator.
To Manually Start the Generator
1.
At either “START/STOP” switch, press and hold the start portion of the switch to start
the generator. Depending on the outside temperature the start process can take up to 15
seconds. Once the generator starts running, release the switch.
2.
An LED above the start switch will light when the generator is running.
3.
For better performance and engine life, especially in colder weather, let the generator
engine warm up for two minutes before turning “ON” 120-volt appliances.
For more information on generator operation and maintenance, refer to the manufacturer’s
owner’s manual.
Transfer switch
For more information, see the
Automatic Transfer Switch (ATS)
section..
NOTE: The diesel (or gas) generator requires 12-volt power from the house
auxiliary batteries to start, and draws diesel fuel (or gas) to operate from the
chassis fuel tank. If the fuel level in the chassis fuel tank drops to or below 1/4
full, the generator will shut off and cannot be re-started until the fuel tank is
filled to above 1/4 full.
Maintenance
During periods of extended storage:
4.
Add a diesel fuel additive to the chassis fuel tank to prevent algae growth (only with a
diesel fueled generator).
5.
Completely fill the chassis diesel fuel tank to prevent water condensation and rust in the
tank (only with a diesel fueled generator).
6.
Cover the end of the generator exhaust pipe with screen to prevent bug and rodent
intrusion.
With the exception of simple items, such as normal maintenance (i.e., oil changes, etc.),
all service work should be done by an authorized repair facility. Improper adjustments can
damage the generator and electrical appliances and can result in a safety hazard.
Follow the
generator owner’s manual for maintenance intervals and recommendations.
Exercising Your Generator
– When storing the generator for extended periods of time, it is
important to run the generator regularly to keep it in good working order. Lack of exercise
can cause moisture build-up in the fuel system resulting in poor performance.
For more information on generator operation and maintenance, refer to the generator own-
er’s manual.
Excessive usage can overheat and damage the generator starter motor. Do not
engage the starter motor for more than 20 seconds at a time. If the generator
does not start after the first attempt, wait at least two minutes before beginning
another start sequence. If the generator does not start after a third attempt,
refer to the generator owner's manual for additional information.
Table of Contents
Maintenance Record
Summary of Contents for ALANTE 2023
Page 1: ...ALANTE 2023 OWNER S MANUAL A subsidiary of Thor Industries Inc...
Page 2: ......
Page 20: ...14 Section 1 Warranty Service Notes Table of Contents Maintenance Record...
Page 32: ...26 Section 3 Pre Travel Information Notes Table of Contents Maintenance Record...
Page 50: ...44 Section 4 Vehicle Operation Notes Table of Contents Maintenance Record...
Page 58: ...52 Section 5 Slideout Systems Notes Table of Contents Maintenance Record...
Page 82: ...76 Section 7 Fuel System Notes Table of Contents Maintenance Record...
Page 114: ...108 Section 10 Appliances Notes Table of Contents Maintenance Record...
Page 116: ...110 Section 11 Electronics Notes Table of Contents Maintenance Record...
Page 134: ...128 Section 14 Travel Camping Storage Checklists Notes Table of Contents Maintenance Record...
Page 138: ...132 Section 15 Additional Information Notes Table of Contents Maintenance Record...