7.7- Programming of con
fl
icting command interlocking
This procedure allows to forbid con
fl
icting actions activated by the
simultaneous pressure of two transmitter function buttons.
Relays concerned by the interlocking will be deactivated (
OFF state
) if an
interlocking is detected..
A transmitter / receiver association must have been realized..
This procedure requires transmitter and receiver.
IMPORTANT :
This programming procedure uses the receiver
jumper
/ microswitch.
Every time
jumper (ORRS and ORRA) is put in short
circuit
microswitch (ORRD) is set on «ON» position,
previously programmed interlockings are erased.
1
ORRS and ORRA receivers :
Switch off the receiver
ORRD receiver :
the receiver can remain powered up throughout the procedure
2
ORRS and ORRA receivers :
install the jumper
to con
fi
gure the settings.
ORRD receiver :
set the microswitch
to the «ON» position
R2
R3
R4
V1 V2 V3
JP1
JP2
JP3
V1 V2 V3
JP1
JP2
JP3
JP4
V1
V3
V2
JP3
ON
OFF
JP1
JP2
ORRS
ORRA
ORRD
3
ORRS and ORRA receivers :
Switch on the receiver
ORRD receiver :
go to the next step
4
V2
and
V3
ORRA
ORRS ORRD
LEDs blink 2 times then go off.