MinPad Configuration
• Data recording auto-start on page 2-15
Figure 2-13. Receiver Configuration – MinPad Tab
Recording Interval parameter
This parameter specifies the message output interval into the log file when
the MinPad FN key (pressed for 1-5 seconds) activates data logging. This
setting is used not only when logging a single log file, but also when logging
board data in AFRM mode. Values are 1-86400 seconds.
The default value is one second.
Elevation Mask for Log File parameter
This parameter specifies the minimum elevation angle for the satellites
whose data will be put in the board files logged when pressing FN.
The default value is five degrees.
File Name Prefix parameter
This parameter specifies what prefix will be added to the names of the board
files created when pressing FN. The prefix can be up to 20 characters long.
The default value is log.
Log file names have the following structure:
<prefix><month><day><sequential alphabet letter>