Command Line Interface
Diagnostics and Identification Commands
26
www.javad.com
4.4. SAVE
The SAVE command is intended to store the unit’s currently used configuration into the User
Configuration file. The configuration stored in the User Configuration file is activated by automatically
after unit’s reboot.
4.5. SLEEP
The SLEEP command determines the sleep mode parameters. The sleeping AW400Tx can be activated
by real-time CLK, DTR/RTS lines, and command received through TTL inputs. The user can select one,
two, or all three conditions.
SLEEP [
Parameter Name
] [
Parameters List
] [
/?
]
5. Diagnostics and Identification Commands
5.1. INFO
The INFO command is used to retrieve the Radio ID along with its Hardware version, the loaded real-
time software version/revision and BootLoader’s version/revision.
INFO [
Parameter Name
] [
Parameters List
] [
/?
]
The INFO command without Parameter Name indicates all values:
Parameter Name
Parameter List
CLK
0 – Do not activate by internal real-time clock
(1 – 255) – Activate by internal real-time clock after 100 to 25500 msec of sleeping
HW
0 – Do not activate through DTR/RTS lines
1 – Activate through DTR/RTS lines
TTL
0 – Do not activate by external sense lines
1 – Activate by external sense lines
GTS
0 – Disable Sleep mode (default)
(1 – 255) – Go to sleep mode if there is no activity in 10 to 2550 msec
Parameter Name
Parameter List
ID
Product ID
SN
Six bytes Serial Number (SN)
HW
1.0 – hardware version in numeric “Major.Minor” format
SW
Ver. 1.0 Rev. A – displays software’s version in numeric “Major.Minor” format and
revision in numeric format (range from 01 to 99) for engineering releases and alphabetic
format (A to Z) for manufacturing releases
BL
Ver. 1.0 Rev. A – displays BootLoader’s version in numeric “Major.Minor”format and
revision in numeric format (range from 01 to 99) for engineering releases and alphabetic
format (A to Z) for manufacturing releases