AT-572
[RE5F22A]
DTC P0780 SHIFT
Revision: November 2006
2006 Altima
DTC P0780 SHIFT
PFP:31940
Description
ECS009HF
●
This malfunction will not be detected while the A/T CHECK indicator lamp is indicating another self-diag-
nosis malfunction.
●
This malfunction is detected when the A/T does not shift as instructed by the TCM. This is not caused by
electrical malfunction (circuits open or shorted) but by mechanical malfunction such as control valve stick-
ing, improper solenoid valve operation, etc.
On Board Diagnosis Logic
ECS009HG
●
This is an OBD-II self-diagnostic item.
●
Diagnostic trouble code “SHIFT” with CONSULT-II or P0780 without CONSULT-II is detected under the
following conditions.
–
When no rotation change occurs between input (turbine revolution sensor) and output (revolution sensor)
and shifting time is long.
–
When shifting ends immediately.
–
When engine revs up unusually during shifting.
Possible Cause
ECS009HH
●
Shift solenoid valve D
(Off error.)
●
Shift solenoid valve E
(Off error.)
●
Pressure control solenoid valve A
(On/Off error.)
●
Pressure control solenoid valve B
(On/Off error.)
●
Pressure control solenoid valve C
(On/Off error.)
●
Hydraulic control circuit
DTC Confirmation Procedure
ECS009HI
CAUTION:
●
Always drive vehicle at a safe speed.
●
Be careful not to rev engine into the red zone on the tachometer.
NOTE:
If “DTC Confirmation Procedure” has been previously performed, always turn ignition switch “OFF”
and wait at least 10 seconds before performing the next test.
After the repair, perform the following procedure to confirm the malfunction is eliminated.
WITH CONSULT-II
1.
Start engine and select “A/T” with “DATA MONITOR” mode in
CONSULT-II.
2.
Make sure that ATF temperature is within the range below.
FLUID TEMP: More than 60
°
C (140
°
F)
If out of range, drive the vehicle to warm up the fluid.
3.
Drive vehicle and allow the following conditions.
SLCT LVR POSI: “D” position
GEAR: 1st
Þ
2nd
Þ
3rd
Þ
4th
Þ
5th position
SHIFTING GEARS - 9J500 MODELS"
.)
4.
If DTC is detected, go to
AT-575, "Diagnostic Procedure"
.
WITH GST
Follow the procedure “With CONSULT-II”.
BCIA0030E