SCOP & P
designh
JÄSPI Inverter Nordic according to EN 14825
20
16
12
8
JÄSPI Inverter Nordic
SCOP
P
designh
SCOP
P
designh
SCOP
P
designh
SCOP
P
designh
5.05
11
5.05
11
4.83
8
4.80
5.9
SCOP 35 Average climate
(Europe)
3.9
12.3
3.9
12.3
3.78
8.3
3.75
6.3
SCOP 55 Average climate
(Europe)
4.25
13
4.25
13
4.05
9.3
4.03
6.8
SCOP 35 Cold climate
3.53
14
3.53
14
3.33
9.8
3.33
7.4
SCOP 55 Cold climate
5.5
13
5.5
13
5.48
9.2
5.43
5.9
SCOP 35 Warm climate
4.5
13
4.5
13
4.48
9.2
4.35
6.3
SCOP 55 Warm climate
1)
Power statements including defrosting according to EN 14511 at heating medium supply corresponding to DT=5 K at 7 / 45.
2)
Nominal flow corresponds to DT=10 K at 7 / 45.
Energy rating, average climate
JÄSPI Invert-
er Nordic-20
JÄSPI Invert-
er Nordic-16
JÄSPI Invert-
er Nordic-12
JÄSPI Invert-
er Nordic-8
Model
SMO
SMO
SMO
SMO
Control module model
35 / 55
35 / 55
35 / 55
35 / 55
°C
Temperature application
A++ / A++
A++ / A++
A++ / A++
A++ / A++
The product’s room heating efficiency class1
)
A+++ / A+++
A+++ / A+++
A+++ / A+++
A+++ / A+++
Space heating efficiency class of the system
2)
1
Scale for the product’s room heating efficiency class A++ to G.
2
Scale for the system’s room heating efficiency class A+++ to G.
The reported efficiency of the package also takes the controller into account. If an external supplementary boiler or solar heating is added
to the package, the overall efficiency of the package should be recalculated.
JÄSPI Inverter Nordic
Chapter 11 |
Technical data
44