*ASON)NTERNATIONAL)NCs

 

501.771.4477  

 

 

 

Page 1 of 12

 

 

 

 

 

Customer Service :  800.255.5766 

Copyright © 2013 Jason International.

OWNER’S MANUAL

Integrity

®

 Soaking, MicroSilk

®

, AirMasseur

®

 

, Whirlpool Baths

INSTALLATION, OPERATION, AND MAINTENANCE

“TO BE REMOVED FOR USE BY THE OCCUPANT.”

49-1013-001

Date    02/13

Jason International, Inc.

 

8328 MacArthur Drive

North Little Rock, AR 72118-2029

www.jasoninternational.com

OWNER’S RECORD

Dealer: 

Date Purchased: 

Date Installed: 

Installer: 

PLACE SERIAL NUMBER CARD WITH 

PRODUCT CONFIGURATION IN THIS BOX

INSPECTION

Inspect the unit prior to installation. In the event of a 
problem, DO NOT install the unit.
  
All components are factory assembled to the bath and the 
unit is water tested and inspected prior to leaving Jason 
International, Inc.

If the carton shows sign of damage, inspect the product 
before accepting and describe the problem on the Bill of 
Lading.

NOTE: Transportation and insurance from Jason’s 
factory are the buyer’s responsibility.

Damage sustained in transit is the responsibility of 
the carrier.
 If damage is discovered, the carrier must 
be immediately notified in writing with a request for a 
representative to inspect the unit. Failure of the carrier 
to respond should be reported to the seller and carrier. 
Always file a freight claim promptly.

The installer is responsible for ensuring that the unit is 
free from defects or shipping damage. In the event of a 
problem, DO NOT install the unit. 

Jason International is not responsible for damage that 
might have been avoided by inspection or testing prior to 
installation.

If the carton shows sign of damage, inspect 

the product before accepting and describe the 

problem on the Bill of Lading.

Damage to the unit during installation will not be covered 
by warranty and is the responsibility of the installer.  
ALL WARRANTY CLAIMS ON ACRYLIC SURFACE 
DAMAGE MUST BE MADE PRIOR TO INSTALLATION.
 
Inspect plumbing and bath surface for missing or damaged 
components. Alert your dealer of any discrepancies.

To protect the unit from damage keep the bath in the 
carton until ready for installation.

EQUIPMENT ACCESS

In accordance with Building Codes, service access to 
all hydrotherapy bath equipment, controls and electrical 
connections must be provided during installation 
(Recommended minimum 28" x 17" [71 x 43 cm]). 
Insufficient access will hinder repair and maintenance. 
Warranty service will not cover costs of providing 
equipment access.

Jason offers an optional removable lateral skirt for all 
rectangular baths. The skirts are available in matching 
acrylic colors and provide convenient access to bath 
equipment, as well as an excellent finished appearance.

The Specification Sheet for this bath contains additional 
technical information.  This sheet can be provided by your 
dealer or accessed online at www.jasoninternational.com.

Summary of Contents for Integrity

Page 1: ...onsible for ensuring that the unit is free from defects or shipping damage In the event of a problem DO NOT install the unit Jason International is not responsible for damage that might have been avoi...

Page 2: ...ylic surface of this bath has been provided with a protective film which helps protect the bath during shipment and installation Additional protection may also be required to protect the acrylic surfa...

Page 3: ...ACTUATOR FULL SUPPORT BASE PUMP MOUNT FULL SUPPORT BASE Dedicated 120V 60 Hz GFCI Protected Service L2 L1 GROUND DEDICATED 240V 50 or 60 Hz GFCI PROTECTED SERVICE NOTE USE THE ABOVE DIAGRAM FOR 240V...

Page 4: ...ipment or other heat producing components of the unit 4 Whirlpool Equipment This Whirlpool bath is provided with an Air On Off switch The pump is pre wired to a control box which has a 36 cord Connect...

Page 5: ...warranty To install the MicroSilk Pump Assembly to the bath the following procedures must be followed Note Do not install the MicroSilk Pump Assembly further than the length of the tubing that is fac...

Page 6: ...isconnect the blower from the air bath plumbing by removing the two 2 screws on the check valve outlet and disconnect the short piece of flex pipe between the check valve and the elbow by removing the...

Page 7: ...start the MicroSilk unit Press the Air On Off button again to stop the MicroSilk unit MicroSilk Unit The MicroSilk unit generates oxygen rich microbubbles that fill the bath MicroSilk units provided...

Page 8: ...th unit and its plumbing are designed to drain after each use whether used as a hydrotherapy bath soaking bath or just taking a shower Air ON OFF Button TheAirOn Offbuttonprovidesasafe andconvenientme...

Page 9: ...on warranty items The serial number can be found on the front page of this manual or on the small card adhered to the back of the bath just above the equipment ALL WARRANTY REPAIRS MUST BE AUTHORIZED...

Page 10: ...re plug is fully inserted into the outlet c Air Switch is disconnected or defective c Check and reconnect if necessary Blower shuts off by itself or before time elapses a Blower motor overheated and t...

Page 11: ...k System usu ally surges b Make sure union is tight on suction side of the purmp Pump does not manually shutoff a Defective keypad or control a Refer to installer dealer Replace keypad or control Pump...

Page 12: ...EXPRESSED OR IMPLIED AS TO ANY MATTER WHATSOEVER INCLUDING THE CONDITION OF THE MERCHANDISE ITS MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ANY WARRANTIES IMPLIED BY LAW AND NOT EF FECTIVELY...

Page 13: ...onstrictors vasodilators hypnotics narcotics or tranquilizers F Persons with a medical history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a phys...