Page 20
5.2. Power installation
Warning!
The electrical connection of equipment shall be carried out by
suitably qualified personnel.
Warning!
All connections shall be made after the power supply is off.
Warning!
Incorrect voltage may damage the equipment.
1) Ensure the input voltage value is within the specified input voltage range.
2) Ensure that the power switch is turned off.
3) Connect the input power cord to the input terminal or plug the power cord into the
corresponding socket (if any) and ensure a good contact.
4) Ground the power supply well. (As shown in the diagram, the European plug has a
grounding terminal, so no additional grounding is required.)
NOTE!
If the input cable needs to be extended, please use a cable with larger cross-sectional
area to reduce the voltage drop, 3x2.5mm
2
or more is recommended.