background image

 

 
 
 

PROPRIETARY NOTICE

 

 
All rights reserved by Janz Tec AG. 
No parts of this technical manual may be modified, copied or reproduced 
in any form or by any means for commercial use without the prior written 
permission of Janz Tec AG, Germany. 
All instructions, information and specification contained in this manual 
are for reference only and remain subject to change without 
announcement. 
 
 

 

em

PC-A500 

 

Embedded Computer System 

 

(Hardware Manual) 

 

Revision 1.0 

Preliminary

 

Refers to product revision 

V 1.0 

Summary of Contents for emPC-A500

Page 1: ... any means for commercial use without the prior written permission of Janz Tec AG Germany All instructions information and specification contained in this manual are for reference only and remain subject to change without announcement emPC A500 Embedded Computer System Hardware Manual Revision 1 0 Preliminary Refers to product revision V 1 0 ...

Page 2: ... hw empc empc a500 doc manual_empc a500_hardware doc Pattern n daten entwicklung ew formblätter entwicklung ew f_manual dot Created as ime 2011 11 15 Last Update ime 2011 11 15 Figure 1 Picture of emPC A500 1 figure likewise Janz Tec AG 2011 Im Doerener Feld 8 ...

Page 3: ...D 33100 Paderborn Germany Tel 49 5251 1550 0 0800 JANZTEC FAX 49 5251 1550 190 Email mail janztec com Internet www janztec com ...

Page 4: ......

Page 5: ... 1 Front Panel Layout 10 2 2 Interfaces 11 2 2 1 RS232 11 2 2 2 RS232 Console 11 2 2 3 RS485 12 2 2 4 CAN 12 2 2 5 Power supply Reset and LEDs 12 2 3 Compact Flash Removal 12 2 4 Battery replacement 13 2 5 Software installation 13 3 Technical Data Specification 14 4 References 16 4 1 Product History 17 4 2 Manual History 17 ...

Page 6: ...00 0 front panel 10 Figure 3 emPC A500 1 front panel 10 Figure 4 emPC A500 2 front panel 10 Figure 5 emPC A500 R3 front panel 10 Figure 6 Power connector 12 List of Tables Table 1 The different variations of emPC A500 8 Table 2 D SUB pin out 11 Table 3 Interfaces connected to D SUB 11 Table 4 CAN connector 12 Table 5 Power connector assignment 12 ...

Page 7: ...will be either decimal or hexadecimal The C notation to identify hexadecimal numbers the 0x prefix is used Low active signal names are suffixed by a character Some parts of the text are important These are visually marked with the following signs Indicates information that when not fully understood or followed causes permanent damage to the system Before using the product this information must be ...

Page 8: ... USB 2 0 2 x 10 100Mbit s Ethernet 2 x CAN SY EPC 50005 emPC A500 R3 VGA 2 x USB 2 0 2 x 10 100Mbit s Ethernet 3 x RS232 1 x CAN SY EPC 50006 emPC A500 1 IO VGA 2 x USB 2 0 2 x 10 100Mbit s Ethernet 1 x RS232 1 x CAN 8 dig IO 24VDC 4 ana input 16bit res and 4 ana outputs 16bit res Table 1 The different variations of emPC A500 The different variations of emPC A500 are attained by the modular assemb...

Page 9: ...32V DC input capability Reset button and Power LED 2 male 9pin D SUB connectors which can be used by the following functional blocks o up to 2xCAN isolated o up to 2xRS232 o up to 2xRS485 optional isolated o UART ports of the CPU module console Power supply monitor Note that not all feature are available simultaneously contact Janz Tec AG for the possibilities configurations ...

Page 10: ...n which configuration the IO module has the connectors supports CAN or RS232 Optional the serial connector can be assembled with RS485 The emPC A500 R3 has two additional D SUB connectors All emPC A500s have jointly a VGA connector two USB connectors two Ethernet connectors the LEDs S1 and S2 the reset button a power LED and a power connector which are mounted on the CPU module The external power ...

Page 11: ...0x7000C000 emPC A500 1 CAN CAN0 mpcan_00 dev pcan_0 MOD_BASE CAN0 CAN0 mpcan_00 dev pcan_0 MOD_BASE emPC A500 2 CAN1 CAN1 mpcan_01 dev pcan_1 MOD_BASE 0x200 Serial 0 Console COM1 ttyS0 0x7000C000 Serial 1 xx ttyS2 MOD_BASE 0x400 Serial 2 xx ttyS3 MOD_BASE 0x500 emPC A500 R3 CAN CAN0 mpcan_00 dev pcan_0 MOD_BASE Table 3 Interfaces connected to D SUB 2 2 1 RS232 The serial interface is implemented b...

Page 12: ... 5 Power supply Reset and LEDs The power supply connector is implemented with a Phoenix Contact Plug type MC1 5 3 ST1F 5 08 BF and is included in delivery The assignment of this connector is shown in Figure 6 and Table 5 Pin Description 1 9 32 VDC 2 NC do not connect 3 GND Figure 6 Power connector Table 5 Power connector assignment 3 2 1 There is a Reset button next to the power connector The LED ...

Page 13: ...opened by removing the four screws at the front Explosion risk in case of improper replacement of the battery Disposal of used batteries according to local regulations Replace only with the same or equivalent type When installing the battery precautions against electrostatic discharge ESD must be taken 2 5 Software installation The boot Flash contains the u boot boot loader software This software ...

Page 14: ...onnectors on front panel with 500mA power supply capability CAN SJA1000 with ISO DIS 11898 TBD isolated from logic and software switchable 120 Ohm resistor Serial Port RS232 Xicor 16V2750 controller with RS232 full featured or RS485 optionally isolated from logic Video Controller CPU internal Memory In the main DDR2 RAM Interface 15pin VGA connector on front panel single channel LVDS on internal c...

Page 15: ... A500 Hardware Manual Technical Data Specification 3 15 Rev 1 0 Janz Tec AG Environmental Specifications assembled system Temperature range 0 50 C operating 20 75 non operating Humidity 0 80 non condensing ...

Page 16: ...ips Semiconductor Jan 04 2000 2 System Reference Manual for A500 Platforms Janz Tec AG Jan 2011 The following titles are books for more in depth reading If a book is in the list it does not explicitly say that it is a good one However there is no book that we haven t learned something from 20 Seal David ARM architecture reference manual Addison Wesley 2000 21 Sloss Andrew et al ARM System Develope...

Page 17: ...n number are related to a PCB redesign Though PCB redesign need not be related to functional changes but might have been done for manufacturing purposes only Version Release Date Name Changes V1 0 13 11 2006 ime Initial version 4 2 Manual History Version Release Date Name Changes V0 1 ime Draft for internal development ...