SHW-MRI-1 MACHINE ROOM INTERCOM  

USER’S MANUAL 

 

 

SHW-MRI-1 

 
 
 
 
 
 

Avire Inc 

415 Oser Avenue, Suite Q, Hauppauge, New York 11788 

Phone: 631 864 3699  Toll Free: 800 527 9156 

Fax: 631 864 2631  Email: [email protected] 

 

          

Janus is a brand of Avire 

Summary of Contents for SHW-MRI-1

Page 1: ...NE ROOM INTERCOM USER S MANUAL SHW MRI 1 Avire Inc 415 Oser Avenue Suite Q Hauppauge New York 11788 Phone 631 864 3699 Toll Free 800 527 9156 Fax 631 864 2631 Email sales us avire global com Janus is a brand of Avire ...

Page 2: ...2 TABLE OF CONTENTS SECTION PAGE OVERVIEW 3 INSTALLATION 4 OPERATION 5 TROUBLESHOOTING 6 SHW MRI 1 CONNECTION DIAGRAM 7 SHW MRI 1 MOUNTING DIAGRAM 8 WARRANTY POLICY 9 RETURN POLICY 10 ...

Page 3: ...ephone line is cut and the SHW MRI 1 is connected in series to that Line using the supplied phone jacks The Incoming phone jack connects to C O or PBX phone line and the Outgoing phone jack connects to the ADA elevator phone The SHW MRI 1 meets requirements for ASME A17 1a 2001 addenda to ASME A17 1 2000 Safety Code for Elevators and Escalators Code 2 27 1 3 Machine Room Communications A means of ...

Page 4: ...d 2 Install the SHW MRI 1 unit on the wall or flat surface with 4 8 32 screws using the 4 keyholes on the back of the unit See Figure 2 3 Plug in the incoming phone line to the Incoming phone jack of the SHW MRI 1 unit If you don t have a modular connector on your phone line wires you need to open up the Incoming phone jack and connect the Incoming phone line to the Green and Red terminals of that...

Page 5: ...l continue until the ADA elevator phone turns ON automatically or someone actually answers the call 4 When the ADA elevator phone has turned ON you will have two way communication 5 The call will be terminated when you hang up the phone on the SHW MRI 1 unit or the elevator phone The LED will start flashing again and then it will turn OFF 6 The SHW MRI 1 and the ADA elevator phone are now ready fo...

Page 6: ... ON THE LINE 3 If the ADA elevator phone does not call out Check the voltage of the phone line on the Telco connector of the SHW MRI 1 unit The same voltage should be shown on the Elev connector of the SHW MRI 1 Note The normal phone line voltage is about 24 52VDC There are cases that the voltage might drop bellow 24VDC if the phone line connection is located far away from the central office or an...

Page 7: ...7 SHW MRI 1 CONNECTION DIAGRAM Figure 1 ...

Page 8: ...8 SHW MRI 1 MOUNTING DIAGRAM Figure 2 ...

Page 9: ...r shall have no obligation under this Limited Warranty or otherwise if the product is altered or improperly repaired or serviced by anyone other than Avire factory service For warranty service contact Avire at 631 864 3699 or 800 527 9156 THERE ARE NO WARRANTIES EXPRESS OR IMPLIED OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HE...

Page 10: ...ines that the product is not functioning an RA Return Authorization number will be issued allowing the installer to return the product directly to Avire for repair replacement or credit Returns with no fault found will result in a bench charge plus shipping costs Returns without an RA number will result in a restocking charge of 25 or more plus shipping costs Need Technical Assistance Call 1 800 5...