Reading out recordings

If you wish to read out the measured data, connect 
the measurement case to a PC via the Ethernet 
connection 

(10) 

. The read-out is implemented via 

the GridVis

®

 software. 

MRG 512-PRO PQ Flex views

LED Network OK

Green: Supply 
voltage is present

LED Batt. OK

Green: UPS 
functioning correctly

Measurement 
transducer

Power Analyser 
UMG 512-PRO

On/off switch

Switch the device off after 
the measurement!

2.

U

L1

U

L2

U

L3

U

L4

U
N

Net  Ok

Batt.  Ok

I / O

L4

L1

L2

L3

N

Spannungseingänge

Differenzstrommessung

I 5

I 6

I L1

I L2

Ethernet

AUX

I L3

I N

Stromwandlereingänge

UMG 512-PRO

Netz  Ok

Batt.  Ok

I / O

L4

L1

L2

L3

N

Voltage inputs

Residual current transformer inputs

I 5

I 6

I L

1

I L

2

Ethernet

AUX

I L

3

I N

Current transformer inputs

U

L1

U

L2

U

L3

U

L4

U
N

Net  Ok

Batt.  Ok

I / O

L4

L1

L2

L3

N

Spannungseingänge

Differenzstrommessung

I 5

I 6

I L1

I L2

Ethernet

AUX

I L3

I N

Stromwandlereingänge

UMG 512-PRO

Netz  Ok

Batt.  Ok

I / O

L4

L1

L2

L3

N

Voltage inputs

Residual current transformer inputs

I 5

I 6

I L

1

I L

2

Ethernet

AUX

I L

3

I N

Current transformer inputs

Supply voltage

Current transformer 
inputs I 

L1

, I 

L2

, I 

L3

, I 

N

Ethernet
connection RJ45

Voltage inputs
U

 L1

, U

 L2

, U

 L3

, U

 L4

, U

 LN

1.

Residual current transformer inputs

5

, I 

6

5.

6.

4.

3.

7.

8.

9.

10.

- 5 -

Summary of Contents for MRG 512-PRO PQ Flex

Page 1: ...H Vor dem Polst ck 6 D 35633 Lahnau Support tel 49 6441 9642 22 Fax 49 6441 9642 30 E mail info janitza com Internet http www janitza com www janitza com Mobile universal measurement device MRG 512 PR...

Page 2: ...sic device 4 Connecting the measurement case 4 Reading out recordings 5 MRG 512 PRO PQ Flex views 5 Measurement transformer settings 6 Example connection voltage measurement 7 Example connection curre...

Page 3: ...Do not work with the device if the front plate has been removed Otherwise you may come into contact with hazardous voltages It is not permitted to use the device with the front plate removed The UMG 5...

Page 4: ...ectronics GmbH Tel no 49 6441 9642 22 This device must only be operated and repaired by specialised personnel Connecting the measurement case 1 Connect the mains cable to the measurement case 1 and co...

Page 5: ...rement 2 Net Ok Batt Ok I O Differenzstrommess I 5 I 6 Eth AUX UMG 512 PRO Netz Ok Batt Ok I O Residual current transformer I 5 I 6 Ether AUX U L1 U L2 U L3 U L4 U N L4 L1 L2 L3 N Spannungseing nge Di...

Page 6: ...A 6 630 A 5 1000 A 4 1500 A 3 2000 A 2 4000 A 1 Setting Rogowski coil 600 mm Flex CT 1A 600 mm Set the current measurement range with the DIP switch 2 in accordance with the table Potentiometer 1 DIP...

Page 7: ...h fuse Max 20mm Locking sleeve with bayonet catch for accommodating a fuse Example connection current measurement N L1 L2 L3 PE I1 I2 I3 IN I5 I6 Voltage measurement terms connections Rogowski coil RC...

Page 8: ...e signs when drawing energy Also check the power factor for plausibility Turn the current transformer if necessary Up to 2 residual current measurements can be selected c Attention Fatal hazard due to...

Reviews: