janitza JPC 100-PRO User Manual And Technical Data Download Page 10

JPC 100-PRO 

www.janitza.com

10

3. 

Product description

3. 1 

Scope of performance

This device is part of a customer-specific 
complete solution. It serves as a user inter-
face and operator interface for the measure-
ment devices used.

The device is intended for:

• Visualization of current and voltage mea-

suring devices in bus systems.

• Measured value monitoring and configu-

ration of connected Janitza measurement 
devices.

For more information on the complete solu-
tion, please refer to the corresponding usage 
information.

3. 2 

Incoming goods inspection

Safe and trouble-free operation of this device 
presupposes proper transport, storage, set-
up and assembly as well as operation and 
maintenance in addition to compliance with 
the safety information and warning notices.

Exercise due caution when unpacking and 
packing the device, do not use force and only 
use suitable tools.

Before installing the device check the follow-
ing: 

• Its flawless mechanical condition by visual 

inspection. 

• The scope of delivery for completeness.

If it can be assumed that safe operation is no 
longer possible:

• Disconnect the device from operation 

immediately!

• Secure the device against being switched 

on again!

It can be assumed that safe operation is no 
longer possible if the device, for example

• Has visible damage. 
• No longer functions despite an intact pow-

er supply.

• Was subjected to extended periods of 

unfavorable conditions (e.g. storage out-
side of the permissible climate conditions 
without adaptation to the room climate, 
condensation, etc.) or transport stress 
(e.g. falling from an elevated position, even 
without visible external damage, etc.).

3. 3 

Intended use

The device is: 

• Intended for installation in switchboard 

cabinets. 

• Not intended for installation in vehicles! 

Use of the device in non-stationary equip-
ment constitutes an exceptional environ-
mental condition and is only permissible 
by special agreement.

• Not intended for installation in environ-

ments with harmful oils, acids, gases, 
vapors, dusts, radiation, etc.

Safe and trouble-free operation of the device 
requires proper transport, storage, assembly, 
installation, operation and maintenance.

Summary of Contents for JPC 100-PRO

Page 1: ...16 1 b 08 2022 Smart Energy Panel JPC 100 PRO User manual and technical data Janitza electronics GmbH Vor dem Polst ck 6 35633 Lahnau Germany Support 49 6441 9642 22 info janitza com www janitza com w...

Page 2: ...JPC 100 PRO www janitza com 2 JPC 100 PRO Smart Energy Panel Doc no 2 100 116 1 b 08 2022 The German version is the original version of the documentation...

Page 3: ...e and reflect the cur rent state of the information available to us Nonetheless we wish to point out that updates of this document are not always possible at the same time as technical refinements are...

Page 4: ...cabinet 9 2 5 Electrically qualified personnel 9 3 Product description 10 3 1 Scope of performance 10 3 2 Incoming goods inspection 10 3 3 Intended use 10 3 4 Scope of delivery 11 3 5 Operating concep...

Page 5: ...validities and distinctions are marked First make sure you have read and under stood the usage information accompany ing the product Keep the usage information associated with the product available fo...

Page 6: ...regulations for devices with built in batteries or rechargeable batteries Do not attempt to open or repair the device the component on your own because other wise all warranty claims become invalid P...

Page 7: ...th 2 2 Hazard levels Warning and safety information is marked by a warning symbol and the hazard levels are shown as follows depending on the degree of hazard DANGER Warns of an imminent danger which...

Page 8: ...breaker fuse Never switch off remove or tamper with safety devices Do not exceed the limit values speci fied in the user manual and on the rat ing plate This must also be observed during testing and c...

Page 9: ...t prevention regulations Safety technology standards Installation commissioning operation disconnection grounding and marking of electrical equipment The requirements concerning personal protective eq...

Page 10: ...isual inspection The scope of delivery for completeness If it can be assumed that safe operation is no longer possible Disconnect the device from operation immediately Secure the device against being...

Page 11: ...rt no Designation 1 15 06 3xx JPC 100 PRO 1 33 03 871 Installation instruc tions INFORMATION All supplied options and design variants are described on the delivery note 3 5 Operating concept You can o...

Page 12: ...about elements on the side 4 Product label with device designation production date part number and serial number 5 Information about connections on the side 6 Conformity markings see section 1 6 7 Re...

Page 13: ...including death Disconnect your system from the power supply before mounting and connecting the device Secure it against being switched on Check to be sure it is de energized Ground and short circuit...

Page 14: ...e the sheet metal of the cabinet see Fig 5 3 Tighten the fastening screw of one retain ing bracket in one corner until the bracket presses against the sheet metal of the cabinet 4 Repeat step 3 for th...

Page 15: ...echnical data see section 8 If no indication appears on the display after connecting the supply voltage check wheth er the supply voltage is within the nominal voltage range 5 3 Connection of the meas...

Page 16: ...100 PRO www janitza com 16 6 Initial commissioning and user interface INFORMATION For information on initial commissioning and the user interface refer to the functional de scription of your applicat...

Page 17: ...nd including death Only electrically qualified personnel are permitted to work on the devices and their components assemblies systems and current circuits Always use your device or component only in t...

Page 18: ...x RJ45 Transmission rate 10 100 1000 Mbit s SD card Available Display Type TFT 16 7 million colors Diagonal 10 1 Resolution 1280 x 800 pixels Display size 217 mm x 135 6 mm 8 54 in x 5 34 in Touchscre...

Page 19: ...www janitza com JPC 100 PRO 19 Dimensional drawings Fig 7 Front view Fig 8 Side view Fig 9 Rear view The figures are for illustration purposes only and are not to scale Dimensions in mm...

Page 20: ...2022 Subject to technical alterations The current version of the document can be found in the download area Janitza electronics GmbH Vor dem Polst ck 6 35633 Lahnau Germany Tel 49 6441 9642 0 info jan...