background image

NOTE: Read ALL instructions over carefully before attempting 

to install the Storm with cone.

If you have any questions please call your local dealer or 

J&D Manufacturing at: 1-800-998-2398.
Or visit our website at: www.jdmfg.com

STORM 

WITH CONE

55” Fiberglass Exhaust Fan

PARTS LEGEND

WARRANTY

J&D Mfg. warrants all products are free from defects in materials and workmanship under 

normal use for the period of one year from date of purchase and our warranty does not 

cover normal or regular wear and tear. J&D Mfg can repair or replace at our option, any 

product or part of the product that is found to be defective.  Our warranty applies to 

materials only and does not include return freight, delivery, loss or damage to personal 

property, cost of removal or installation, any incidental or consequential damages or labor. 

This warranty does not apply to products which are misused, abused, altered, improperly 

installed or subject to negligence. All warranties must be approved through our warranty 

department. The original purchaser must present a copy of the invoice for the defective 

product.  One year is our standard warranty unless specified on our literature or in the 

installation instructions/user manuals.  

INSTALLATION HARDWARE IS NOT PROVIDED

IS198-09H

RECOMMENDED TOOLS FOR INSTALLATION AND ASSEMBLY  

(NOT PROVIDED)

Measuring 

Tape 

Safety Glasses

INCLUDED ASSEMBLY HARDWARE - TO SCALE

Guard

Shutter

Housing

(8) Flat Washer

5/16

1/2"

Socket

Socket Wrench

Drill

 and Drill Bits

3/16”

3/8”

(8) 3/16” x 1/4"

Aluminium Rivet

(8) 3/16”ID x 1/2"OD

Aluminium Rivet

Rivet Gun

(8) Shutter Clips

(13) Phillips Truss Bolt

5/16”-18 x 1”

(13) Nylock Flange Nut

5/16”-18

Cone

Construct structurally sound 59¾” square finished opening.

59 ¾”

59 ¾”

FINISHED

OPENING

(Inside Dimensions)

NOTE: Read

 ALL

 instructions over carefully before attempting 

to install the Storm with cone

55” Fiberglass Exhaust Fan

Correct orientation of fan. From the inlet side, the motor will be located 

above and to the right of the shaft.

Motor

View from inlet 

side of fan

Phillips

Screwdriver

Summary of Contents for STORM WITH CONE

Page 1: ...led or subject to negligence All warranties must be approved through our warranty department The original purchaser must present a copy of the invoice for the defective product One year is our standard warranty unless specified on our literature or in the installation instructions user manuals INSTALLATION HARDWARE IS NOT PROVIDED IS198 09H RECOMMENDED TOOLS FOR INSTALLATION AND ASSEMBLY NOT PROVI...

Page 2: ...as shown in illustration These will be your guides for properly installing the cone in step 5 3 Attach all 8 shutter clips with a rivet gun using 8 3 16 rivets and 8 3 16 washers Review the illustrations below for placement and assembly 2a Fan Flange Shutter Clip Rivet Washer 2b Rivet Washer Fan Flange Shutter Clip 2 155 8 155 8 155 8 155 8 155 8 155 8 187 8 187 8 e d g e o f v e n t u r i 2 ...

Page 3: ...included 4 Interior of structure Exterior of structure Using the 5 predrilled holes in the cone drill matching holes in venturi and secure with 5 5 16 Phillips Truss Bolts and 5 5 16 Nylock Nuts Insert bolt from the interior of the cone and secure with nut on exterior 6 Assembly Side View Connecting power to the unit Install manual disconnect switch inside building adjacent to fan Route wire to mo...

Page 4: ...ovative quality J D and Pruden ventilation products www jdmfg com Swivel top and side shutter clips open Set bottom shutter flange into bottom shutter clips Secure shutter by swiveling top and side shutter clips over shutter flange 9 ...