Hatchery Disinfectant Manual
OPERATION
GENERAL
Once the atomizers have been installed, the cable rout-
ing completed and the dilution tanks filled with
disinfectant solution, the system can be programmed
for automatic operation.
THE ELECTRONIC CONTROLLER
The Controller can be programmed to operate and
control two independent zones. Programming is en-
tered using the keypad on the front panel of the
controller, which in turn activates the menu-based dis-
play. Refer to Figure 2 on page 7.
The controller has the capacity to program each of
the two zones for up to 30 days, with automatic re-
peat cycling of a 2 to 30 day cycle.
Plug the unit’s electrical cord into a wall outlet (two
or three prong receptacle, as available). Press the
POWER ON/OFF switch on the keypad.
On initial power up, the LED panel will display the
following information:
JAMESWAY
next message:
VERSION 1.09
next:
DISINFECTANT
CONTROLLER
The controller will then go into operation
if there is a
program already in memory. The unit will then dis-
play the following:
3:30:15 PM
1 OFF 4 ON
Note: In the event of power failure, outages, in-
terruptions or when switched off, the internal clock
and program are retained by the long life lithium
battery cell. This cell is located inside the control-
ler (refer to page 11 for replacement instructions).
Note: If an error message appears at start up,
refer to Appendix A for troubleshooting.
Zone 1 is on the
first day of its
program and the
output is OFF
Zone 2 is on the
fourth day of its
program and the
output is ON.