background image

EN 14604:2005

0832-CPD-1674

1050a/01

Silence function

Use the silence function if the smoke alarm is exposed to cooking fumes or 

false alarms. When the alarm siren is on press down the smoke alarm’s front 

surface for 3 seconds until the alarm sound stops. The smoke alarm will then go 

over to the silent mode for approximately eight minutes. After eight minutes the 

smoke alarm will return to the normal operation mode. Note that if an alarm is 

caused by very thick smoke, the alarm siren will continue despite the use of the 

silence function.

5. Maintenance

Test your smoke alarm every week

Test your smoke alarm by pressing down the cover for 3 seconds. You should 

hear a couple of chirps.

Battery replacement

The smoke alarm contains three 3V lithium batteries (IEC-CR2450). Their 

service life is approximately 5 years. When the batteries are running low, the 

smoke alarm will produce an alarm sound approximately every 30 seconds, run-

ning for at least 30 days. Please change the battery as soon as possible.

Recommended battery brands: 

MALAK CR2450 Lithium Cell 3V

ENERGIZER CR2450 Lithium Cell 3V 

SONY CR2450 Lithium Cell 3V

rest batteries by turning the smoke alarm upside down and shaking it gently. 

Look up the terminal sign of the new batteries and put them into the chamber 

in such way that minus sign faces the minus sign terminal at the bottom of the 

chamber. Install rest of the batteries in the same way on top of each other.

WARNING: Lithium batteries can explode or cause burns if not installed prop-

erly. Use only recommended battery type and brands.

After changing the batteries always test the performance of the smoke alarm. 

If the smoke alarm doesn’t work correctly after the battery changing please 

contact the manufacturer.

The mounting plate does not attach to the main unit if batteries are not installed 

properly or are missing!

Clean your alarm at least once a year

Take off the smoke alarm by turning it counterclockwise. Vacuum clean the main 

unit of the smoke alarm gently. After cleaning press the HUSH button at the 

back of the main unit and reinstall your alarm. Always test it after cleaning.

Do not modify or paint the smoke alarm.

Disposal

The smoke alarm should be disposed as normal electronic waste. Follow your 

local guidelines on how to dispose electronic waste.

6. Technical Data

Voltage of 9V Noise level 85dB / 3 meters Power consumption 15mA Operating 

Temperature 0°C – 45°C Humidity Max 90% (RH) Adhesive tape holding temp. 

-35°C – 93°C

7.Warranty

Jalo Helsinki smoke alarms have a 5 year warranty starting on the date of 

purchase. If defects or faults should appear in the smoke alarm during the war-

ranty period, the product will be repaired or exchanged for a new one when sent 

to Jalo Helsinki Ltd. The warranty covers manufacturing, design and material 

defects when the smoke alarm has been operated according to the instructions 

provided in the manual and the warranty period has not expired. If the smoke 

alarm or some parts of it are exchanged during the warranty period their war-

ranty expires on the date of the original warranty date.

The warranty will be void if the product is not used, maintained or tested in 

accordance with the instructions, if the damage or defect is due to wilful neglect 

or negligence by anyone other than Jalo Helsinki Ltd, if the product has been 

altered, the product has been treated violently or the customer does not have 

a receipt for the purchase. The warranty does not cover batteries or setup costs.

Jalo Helsinki Ltd liabilities on the sale of the smoke alarm will in no case exceed 

the equivalent to a cost of a new smoke alarm. Jalo Helsinki Ltd is not respon-

sible for any loss or damage caused by a malfunctioning smoke alarm, even 

when the loss or damage could be the result of a malfunctioning smoke alarm 

or an omission by the manufacturer. This warranty shall not have an effect on 

consumer rights in respect of Consumer Protection Law or in respect of the 

purchase agreement between the consumer and the distributor.

Manufacturer

Jalo Helsinki Ltd. P.O Box 131, 00181 Helsinki Finland

Copyright 2010 Jalo Helsinki Ltd. All rights reserved. Jalo is a registered trade-

mark of Jalo Helsinki Ltd. RCD 001707050. 

SMOKE ALARM MANUAL ENGLISH 

KUPU  

Contents

1.Read this before you install 

2.Locations 

3.Installation 

4.Operation

5.Maintenance

6.Technical data 

7.Service & Warranty

P/N 00061

1. Read this before you install

Thank you for purchasing a Jalo smoke alarm. To ensure maximum safety for 

you and your family please read all the instructions before you install the smoke 

alarm.

If you install this smoke alarm for someone else you must leave this manual or 

a copy of it with the end user.

This smoke alarm is suitable for use in leisure accommodation vehicles (LAV) 

such as caravans and boats.

2. Locations

Recommended Locations

alarm in every bedroom and corridor. Smoke alarms should be placed in the 

Place a smoke alarm at the top of every stairway.

Avoid these locations Near the wall or the corner Do not install the smoke alarm 

within 50 cm from a wall or a corner.

Humid places

Avoid installing the smoke alarm in a location near a shower or a kitchen,where 

vapors or fumes may cause false alarms.

Air vents

may prevent the smoke from reaching the detection chamber of the alarm.

Insect infested places

Avoid installing the smoke alarm in a location which is insect infested. Insects 

could clog the openings of the detection chamber.

Dead air places

If you have a peaked ceiling, install the smoke alarm at least 10 cm lower than 

the peak of the ceiling.

Fluorescent lights

3. Installation

This smoke alarm can be installed in two ways: (1) fast installation with 3M 

double-sided adhesive tape or (2) with the screws provided in the package.

Please note that the mounting plate does not attach to the main unit if batteries 

are not installed properly or they are missing!

Installation guide is on the other side of this manual.

4. Operation and testing This smoke alarm uses a photoelectric detection 

method.

Test your smoke alarm every week by pressing down the front surface for about 

3 seconds until the alarm siren starts. The entire surface of the smoke alarm 

functions as a test button.

The alarm noise level is 85 dB at a three meter distance from the device.

If your smoke alarm malfunctions, please contact your distributor or the manu-

barcode next to the battery compartment.

Sound

Operation 

mode

Alarm mode  

Test mode

Low-Battery 

mode

Fault mode

Silence mode

Three loud 

chirps followed 

by two second 

silence. 

One short 

chirp every 30 

seconds.

One short 

chirp every 30 

seconds.

Two chirps 

per second 

followed by a 

two second 

pause.

Indicator Led

every second

every 30 

seconds.

every 30 

seconds.

every second.

every 30 

seconds.

every eight 

seconds.

Operational

The smoke 

alarm enters 

the alarm mode 

if smoke is 

detected.

Flash and 

chirp have 15 

second differ-

ence.

Flash and chirp 

at the same 

time

The smoke 

alarm enters the 

test mode after 

pressing the 

whole surface 

button down for 

3 seconds. The 

device enters 

the silence 

mode if button 

is pressed down 

longer than 3 

seconds.

Normal opera-

tion mode

The smoke 

alarm enters 

the silence 

mode after 

pressing down 

the whole 

surface button 

for longer than 

three seconds.

Importer Segula GmbH, 50969 Köln  www.segula.de