SP-5000M-PMCL / SP-5000C-PMCL
- 53 -
7.7. RCT mode
Until the trigger is input, the camera operates continuously and the video signal for the
auto-iris lens is output. At this moment, the video signal, FVAL and LVAL are output but DVAL is
not output. When the trigger is input, the fast dump is activated to read out
the electronic charge very quickly, after which the accumulation and the readout are
performed. When the accumulated signal against the trigger is read out, FVAL, LVAL and DVAL
are output too.
Primary settings to use this mode
Trigger Mode = ON
Exposure Mode = Timed
Trigger Option = RCT
Table – 41 Minimum trigger interval (1X8–1Y)
Trigger Mode
Readout Mode
Time (Min. Trigger Period)
Reset Continuous
Trigger Mode
(Note2)
Full
30.9 ms + Exposure time + 1.562 ms
AOI Center 2/3
21.5 ms + Exposure time + 1.562 ms
AOI Center 1/2
15.5 ms + Exposure time + 1.562 ms
AOI Center 1/4
7.7 ms + Exposure time + 1.562 ms
AOI Center 1/8
3.9 ms + Exposure time + 1.562 ms
V Binning ON (Full)
(Note1)
15.5 ms + Exposure time + 1.562 ms
Note1
:
SP-5000M-PMCL only
Note2
:
Trigger Overlap “Readout” is not available for this trigger mode.
t1
t2
Trigger
CMOS
Exposure
Exposure
Active
FVAL
DVAL
Fig.25 RCT mode timing
t1
t2
28L
9L
~
10L