SP-5000M-PMCL / SP-5000C-PMCL
- 19 -
Table - 10 Pulse Generator default settings
5.4.1 Clock Pre-scaler
Clock pre-scaler (Divide Value) can set the dividing value of the frequency divider (12-bit
length) and the sensor clock is used for this. Four built-in pulse generators work by the
same clock. In the SP-5000-PMCL, the sensor clock is 48 MHz.
5.4.2 Pulse Generator Selector
This is where you select one of the 4 pulse generators in order to set or modify its
parameters.
Table - 11
Pulse Generator setting
Display Name
Value
Clock Pre-scaler
1
Pulse Generator
Selector
Pulse Generator
Length Start
Point
End
Point
Repeat
Count
Clear
Source
Clear
Inverter
Clear
Activation
Clear
Sync
Mode
-
Pulse Generator 0
1
0
1
0
Off
True
Off
Async
Mode
-
Pulse Generator 1
1
0
1
0
Off
True
Off
Async
Mode
-
Pulse Generator 2
1
0
1
0
Off
True
Off
Async
Mode
-
Pulse Generator 3
1
0
1
0
Off
True
Off
Async
Mode
Note:]
When Pulse Generator Repeat Count is set to “0”, the camera is operating in free-running mode.
However, based on the above default settings, Length=1, Start Point=0 and End Point=1, Pulse
Generator stops at High output. Therefore, if Start Point=0 and End Point=1 are configured, Length should
be
“
2
”
as the minimum active width.
Trigger Selector
item
Description
Pulse Generator
0
If Pulse Generator 0 is selected, Length, Start Point, End Point, Repeat Count, Clear Source, Clear
Inverter, Clear Activation and Clear Sync Mode of Pulse Generator 0 are displayed under the
selector.
Pulse Generator
1
If Pulse Generator 1 is selected, Length, Start Point, End Point, Repeat Count, Clear Source, Clear
Inverter, Clear Activation and Clear Sync Mode of Pulse Generator 1 are displayed under the
selector.
Pulse Generator
2
If Pulse Generator 2 is selected, Length, Start Point, End Point, Repeat Count, Clear Source, Clear
Inverter, Clear Activation and Clear Sync Mode of Pulse Generator 2 are displayed under the
selector.
Pulse Generator
3
If Pulse Generator 3 is selected, Length, Start Point, End Point, Repeat Count, Clear Source, Clear
Inverter, Clear Activation and Clear Sync Mode of Pulse Generator 3 are displayed under the
selector.