RM-67X Series
74
Appendix
8.3.84
ALC Window – Upper Left X
Function
Command String
Camera Response
Set ALC Window Upper Left X
value
:ULX=[DDD]<cr>
:o<cr>
Set the upper left x co-ordinate for the ALC control window.
[DDD] is the size parameter with a range of 1-766. This
command applies to camera models TM-770, TMC-773, and
TMC-775.
Get ALC Window Upper Left X
value
:ULX?<cr>
:oULX[DDD]<cr>
Enquire current upper left x co-ordinate for ALC control
window. [DDD] is the current value with a range of 1-766.
This command applies to camera models TM-770, TMC-773, and
TMC-775.
8.3.85
ALC Window – Upper Left Y
Function
Command String
Camera Response
Set ALC Window Upper Left Y
value
:ULY=[DDD]<cr>
:o<cr>
Set the upper left Y co-ordinate for the ALC control window.
[DDD] is the size parameter with a range of 1-492. This
command applies to camera models TM-770, TMC-773, and
TMC-775.
Get ALC Window Upper Left Y
value
:ULY?<cr>
:oULY[DDD]<cr>
Enquire current upper left Y co-ordinate for ALC control
window. [DDD] is the current value with a range of 1-492.
This command applies to camera models TM-770, TMC-773, and
TMC-775.
8.3.86
U-Sat
Function
Command String
Camera Response
Set U-Sat
:USA=[DDD]<cr>
:o<cr>
Set the U saturation value for the TM-773. [DDD] is the
saturation value with a range of 0-63.
Get U-Sat
:USA?<cr>
:oUSA[DDD]<cr>
Enquire current U saturation value for the TM-773. [DDD] is
the saturation value with a range of 0-63.
Summary of Contents for RM-670
Page 2: ......
Page 10: ...RM 67X Series x List of Tables List of Tables Table 1 RM 67X Product Specifications Table 43 ...
Page 13: ...Hardware Introduction 13 RM 67X Series Figure 1 RM 67X System Configuration ...
Page 17: ...Hardware Installation 17 RM 67X Series Figure 5 15P 02 9P FULL Cable ...
Page 40: ...RM 67X Series 40 Functional Options ...
Page 80: ...RM 67X Series 80 Appendix ...
Page 81: ......