Appendix
71
RM-67X Series
8.3.74
SHD Level
Function
Command String
Camera Response
Set SHD Level
:SHD=[DD]<cr>
:o<cr>
Set the SHD level. [DD] is the level value with a range of 0-47.
This command applies only to camera models TM-770, TMC-
773, and TMC-775.
Get SHD Level
:SHD?<cr>
:oSHD[DD]<cr>
Enquire current SHD level. [DD] is the current value with a
range of 0-47. This command applies only to camera models
TM-770, TMC-773, and TMC-775.
8.3.75
Sharpening Gain - SHG
Function
Command String
Camera Response
Set Sharpening Gain
:SHG=[DDD]<cr>
:o<cr>
Set the advanced color sharpening gain value. [DDD] is the
value with a range of 0-127. This value maps to a multiplier
value of x1.0 – x2.0. This command applies only to camera
models TMC-773 and TMC-775.
Get Sharpening Gain
:SHG?<cr>
:oSHG[DDD]<cr>
Enquire current sharpening gain value. [DDD] is the current
value with a range of 0-127. This value maps to a multiplier
value of x1.0 – x2.0. This command applies only to camera
models TMC-773 and TMC-775.
8.3.76
SHP Level
Function
Command String
Camera Response
Set SHP Level
:SHP=[DD]<cr>
:o<cr>
Set the SHP level. [DD] is the level value with a range of 0-47.
This command applies only to camera models TM-770, TMC-
773, and TMC-775.
Get SHP Level
:SHP?<cr>
:oSHP[DD]<cr>
Enquire current SHP level. [DD] is the current value with a
range of 0-47. This command applies only to camera models
TM-770, TMC-773, and TMC-775.
Summary of Contents for RM-670
Page 2: ......
Page 10: ...RM 67X Series x List of Tables List of Tables Table 1 RM 67X Product Specifications Table 43 ...
Page 13: ...Hardware Introduction 13 RM 67X Series Figure 1 RM 67X System Configuration ...
Page 17: ...Hardware Installation 17 RM 67X Series Figure 5 15P 02 9P FULL Cable ...
Page 40: ...RM 67X Series 40 Functional Options ...
Page 80: ...RM 67X Series 80 Appendix ...