User Manual (Ver. 1.0) - Setting List
GOX-5105MC-5GE | GOX-8105MC-5GE | GOX-12405MC-5GE | GOX-16205MC-5GE | GOX-20405MC-5GE | GOX-24505MC-5GE
- 131 -
MultiROIControl
Configure settings for Multi ROI.
Related Topic:
Note:
Refer to
Functions That Cannot Be Used Together
for usage restrictions.
Multi ROI Control Item
Setting
Range
Default
Value
Description
MultiRoiMode
0:Off
1:On
0
Enable/disable Multi Roi.
MultiRoiIndex
0 ~ 7
0
Select the index for the Multi Roi mode.
MultiRoiWidth
-
-
Set the width for the selected Multi Roi index.
Setting Range: 96 ~ [WidthMax - MultiRoiOffsetX], Step 8
Default
GOX-5105MC-5GE: 304
GOX-8105MC-5GE: 352
GOX-12405MC-5GE: 512
GOX-16205MC-5GE: 664
GOX-20405MC-5GE: 560
GOX-24505MC-5GE: 664
MultiRoiHeight
-
-
Set the height for the selected Multi Roi index.
Setting Range: 8 ~ [HeightMax - MultiRoiOffsetY], Step 2
Default
GOX-5105MC-5GE: 258
GOX-8105MC-5GE: 356
GOX-12405MC-5GE: 376
GOX-16205MC-5GE: 380
GOX-20405MC-5GE: 564
GOX-24505MC-5GE: 576
MultiRoiOffsetX
-
-
Set the horizontal offset for the selected Multi Roi index.
Min
: The minimum value of the range where each Index does not overlap.
Max
: The maximum value of the range where each Index does not overlap.
Step
: 8
Default
: (Index number - 1) x MultiRoiWidth