User Manual (Ver.1.4) - Main Functions
GOX-5105MC-CXP | GOX-8105MC-CXP | GOX-12405MC-CXP | GOX-16205MC-CXP | GOX-20405MC-CXP | GOX-24505MC-CXP
- 33 -
Trigger Control
Related Setting Items:
The camera allows the following controls to be performed via external trigger signals.
TriggerSelector
Description
AcquisitionStart Start image acquisition in response to the external trigger signal input.
AcquisitionEnd
Stop image acquisition in response to the external trigger signal input.
FrameStart
Start capturing a one-frame image in response to the external trigger signal input.
Note:
The FrameStart Trigger can only be used when the
setting is set
to
Timed
.
Notes:
l
The settings for exposure control and triggers are related to each other. Be sure to configure
the settings described in
l
You can delay when exposure actually starts after a trigger is received for a specific amount
of time by configuring
TriggerDelay
.
Select the trigger type with TriggerSelector, and set the following items for each trigger.
TriggerMode
Switch enable or disable.
TriggerSource
Select the source signal (PulseGenerator0-3, UserOutput0-3, Software, Line5 Opt In,
Line7 Cxp In, Nand0 Out, Nand1 Out).
Note:
Trigger can be executed by TriggerSoftware[TriggerSelector] command only
when Software is set.
TriggerActivation Sets the polarity of the trigger signal.
TriggerDelay
You can specify a delay after receiving the trigger signal until the trigger is enabled.