GO-5100MC-PGE | GO-5101MC-PGE | User Manual (Ver. 2.0)
Settings List
- 81 -
Acquisition
Control Item
Setting
Range
Default
Description
Trigger
Activation
Rising Edge
Falling Edge
Level High
Level Low
Rising Edge
Select the polarity of the trigger signal (i.e., location of signal at which trigger is
applied).
Trigger OverLap
Off
Readout
Off
Select the trigger overlap operation.
Trigger Delay
(μs)
0 ~ 500000
0
Sets the time to delay the trigger.
Exposure Mode
Off
Timed
TriggerWidth
Timed(control via
exposure time)
Select the exposure mode.
Related Topic:
Exposure Time
8 bit: 1 ~
7999810
10/12 bit: 1 ~
7999630
43864
Set the exposure time. The maximum value when
Trigger Mode
is set to
Off
varies depending on the [Acquisition Frame Rate Raw] value.
Exposure Auto
Off
Continuous
Off
Set whether to enable auto exposure.
EventControl
Related Topic:
Configure event control settings.
Event Control Item
Setting Range
Default
Description
Acquisition Mode
AcquisitionTrigger
FrameStart
FrameEnd
FVAL Start
FVAL End
ExposureStart
ExposureEnd
Line2RisingEdge
Line2FallingEdge
Line3RisingEdge
Line3FallingEdge
Line5RisingEdge
Line5FallingEdge
AcquisitionTrigger
Select the event for which to send notifications.
Event Notification
Off
On
Off
Select whether to output event messages.