User Manual (Ver. 2.0) - Main Functions
GO-5000M-PMCL | GO-5000M-PMCL-EP | GO-5000M-PMCL-UV
- 78 -
Timed Mode
This mode captures image(s) with a preset exposure time by using the external trigger. An additional
setting determines if the trigger pulse can be accepted during the exposure period.
Primary settings to use this mode
l
Acquisition Mode = Single frame, Multi-frame or Continuous
l
Trigger Mode = ON
l
Exposure Mode = Timed
Trigger Mode
Readout Mode
Time (Min. Trigger Period)
Timed Exposure Mode
Trigger Mode ON
Full
8.01 μs
AOI Center 2/3
8.01 μs
AOI Center 1/2
8.01 μs
AOI Center 1/4
8.01 μs
AOI Center 1/8
8.01 μs
V Binning ON (Full)
8.01 μs
Trigger minimum interval (Trigger Overlap = Readout) (1X8–1Y, 8-bit, CL Clock=72.85 MHz)
t1
t2
t3
10μ (Min.)
18μ
6L to 7L