GO-5000M-PGE | GO-5000M-PGE-UV | User Manual (Ver. 2.0)
Main Functions
- 49 -
Acquisition Control
Acquisition control contains the following commands.
Command
Parameter
Description
Acquisition Mode
Single Frame
One frame can be output by AcquisitionStart command
Multi Frame
The number of frames which is specified in Acquisition Frame Count,
are output by AcquisitionStart command
Continuous
Images are continuously output by AcquisitionStart command until
AcquisitionStop command is input.
Acquisition Start
No (EXE
command)
Start Acquisition
Acquisition Stop
No (EXE
command)
Stop Acquisition
Acquisition Frame
Count
1 ~ 255
Set the number of frames to be used in Multi Frame mode.
Acquisition Frame
Rate
0.125 to Maximum
FrameRate
Set the frame rate in fps value
Acquisition Frame
Rate Raw
8sec to Minimum
FramePeriod
Set the frame rate in Frame period (μs)