GO-2400M-PMCL-1 | GO-2400C-PMCL-1 | User Manual (Ver. 1.0)
Short ASCII Command List
- 104 -
User Set Control (Short ASCII Command)
Name
Access
Short
ASCII
Values
Default
Description
UserSetLoad
(R)/W
LD
0: Default
1: UserSet1
2: UserSet2
3: UserSet3
0
LD=[Param.]<CR><LF>
LD?<CR><LF>
Load user settings.
UserSetSave
(R)/W
SA
1: UserSet1
2: UserSet2
3: UserSet3
1
SA=[Param.]<CR><LF>
SA?<CR><LF>
Save the current setting values as user settings.
Counter and Timer Control (Short ASCII Command)
Name
Access
Short
ASCII
Values
Default
Description
Counter0EventSource
R/W
CE0
0:Off
1:FrameTrigger
2:FrameStart
3:ExposuerStart
4:FrameTransferEnd
0
CE0=[Param.]<CR><LF>
CE0?<CR><LF>
Select the counter event signal for which to read the
count value(for Counter0).
Counter1EventSource
R/W
CE1
0:Off
1:FrameTrigger
2:FrameStart
3:ExposuerStart
4:FrameTransferEnd
0
CE1=[Param.]<CR><LF>
CE1?<CR><LF>
Select the counter event signal for which to read the
count value(for Counter1).
Counter2EventSource
R/W
CE2
0:Off
1:FrameTrigger
2:FrameStart
3:ExposuerStart
4:FrameTransferEnd
0
CE2=[Param.]<CR><LF>
CE2?<CR><LF>
Select the counter event signal for which to read the
count value(for Counter2).
Counter0Reset
(R)/W
CR0
1
-
CR0=1<CR><LF>
Reset Counter 0.
Counter1Reset
(R)/W
CR1
1
-
CR1=1<CR><LF>
Reset Counter 1.
Counter2Reset
(R)/W
CR2
1
-
CR2=1<CR><LF>
Reset Counter 2.
Counter0Value
R/O
CV0
0 ~ 65535
0
CV0?<CR><LF>
Display the Counter0 value.