AP-1600T-USB | AP-3200T-USB | User Manual (Ver. 2.0)
Main Functions
- 35 -
During Continuous Operation
This scenario is when
FrameStart
trigger is
Off
or
ExposureMode
is
Off
.
Note:
See "
" for the H_Period, A, B, and PackValue.
1. Maximum frame rate of sensor output
Sensor FR
=
1 / {H_Period × ( A )}
2. Maximum frame rate by interface
Interface FR
=
3000 × 1000000 / (Height × Width × PackValue)
3.
Maximum frame rate
FR_Cont
=
Min(Sensor FR, Interface FR)
When the ExposureTime is longer than the FramePnterval
1. Maximum exposure time at maximum frame rate
MaxExposureTime_TrOlrd
=
(1 / FR_Cont)
-
(B × H_Period)
2. Exposure time outside of Frame Period
NonOverlapExposureTime
=
ExposureTime
-
MaxExposureTime_TrOlrd
Note:
However, NonOverlapExposureTime calculation results that are 0 or below will be considered
as 0.
3.
Maximum frame rate
FR_ContLongExposure
=
1/{(1/FR_Cont)
+
NonOverlapExposureTime}