AP-1600T-USB | AP-3200T-USB | User Manual (Ver. 2.0)
Parts Identification
- 14 -
③
POWER/TRIG LED
Indicates the power or trigger input status.
LED
Status
Lit amber
Camera initializing.
Lit green
Camera in operation.
Blinking
green
During operation in trigger mode, trigger signals are being input.
Note:
The blinking interval is not related to the actual input interval of the external
trigger.
④
DC IN / Trigger IN Connector (12-pin Round)
Connect the cable for DC IN / Trigger IN here.
HR-10A-10R-12PB (71) (Hirose Electric or equivalent)
Pin No.
Input/Output
Signal
Description
1
GND
2
Power In
DC In
DC 12 V ~ 24 V ± 10%
3
In
Opto In 2 -
Line 6
4
In
Opto In 2 +
5
In
Opto In 1 -
Line 5
6
In
Opto In 1 +
7
Out
Opto Out 1 -
Line 2
8
Out
Opto Out 1 +
9
Out
TTL Out 1
Line 1
10
11
Power In
DC In
DC 12 V ~ 24 V ± 10%
12
GND
Note: