Pulse Generators
Item
Setting Range
Default
Description
Clock Pre-scaler
1~ 4096
165
Set the division value for the prescaler (12-bit) using the
pixel clock as the base clock.
Pulse Generator Clock
(MHz)
0.018127 ~ 74.25
-
Set the clock used for the pulse generator. This value is
calculated based on the Clock Pre-Scaler value.
Pulse Generator Selector Pulse Generator 0 ~ 3
Pulse
Generator 0
Select the pulse generator.
Pulse
GeneratorLength
1 ~ 1048575
30000
Set the maximum count up value using clock value.
Pulse Generator
LengthMs (ms)
1 / PulseGeratorClock(MHz)
~
1048575 / PulseGeneratorClock
(MHz)
66.6667
Set the maximum count up value using ms. This value is
calculated based on the Pulse Generator Length value. The
setting range varies depending on the Clock Pre-Scaler
value.
Pulse Generator
Frequency (Hz)
((PulseGeneratorClock (MHz)) ÷
1048575) x 1000000
~
(PulseGeneratorClock (MHz) x
1000000)
15
Set the maximum count up value using frequency. This
value is calculated based on the Pulse Generator Length
value.
Pulse Generator Start
Point
0 ~ 1048574
0
Set the start point for the High interval using clock value.
When the counter reaches this value, the output becomes 1.
Pulse Generator Start
PointMs (ms)
0 ~ (1048575 /
PulseGeneratorClock (MHz))
0
Set the start point for the High interval using ms. When the
counter reaches this value, the output becomes 1. The
setting range varies depending on the Clock Pre-Scaler
value.
Pulse Generator End
Point
1 ~ 1048575
15000
Set the start point for the Low interval using clock value.
When the counter reaches this value, the output becomes 0.
Pulse Generator End
PointMS (ms)
(1 / PulseGeneratorClock (MHz))
~
(1048575 / PulseGeneratorClock
(MHz))
33.3333
Set the start point for the Low interval using ms. When the
counter reaches this value, the output becomes 0. The
setting range varies depending on the Clock Pre-Scaler
value.
Pulse Generator
pulse- width (ms)
-
33.3333
Display High interval width for the pulse in ms. This is a
calculation of the time between the Start Point and End
Point. The setting range varies depending on the Clock Pre-
Scaler value.
Pulse Generator
Repeat Count
0 ~ 255
0
Set the repeat count for the counter. When this is set to 0,
the counter will be free-running with limitless repeating.