AP-1600T-PMCL | AP-3200T-PMCL | User Manual (Ver. 2.0)
Setting List (Feature Properties)
- 87 -
DigitalIOControl
Related Topic:
GPIO (Digital Input/Output Settings)
Configure settings for digital input/output.
Digital IO Control
Item
Setting Range
Default
Description
Line Selector
Line1-TTLOut1
Line2-OptOut1
Line5-OptIn1
Line6-OptIn2
Line7-CC1
NAND0In1
N AND0In2
NAND1In1
NAND1In2
Line2-
OptOut1
Select the input/ output to configure.
Line Mode
Input
Output
Output
Display the input/ output status (whether it is input or output).
Line Inverter
True
False
False
Enable/disable polarity inversion for the selected input
signal or output signal.
Line Status
Related Topic:
True
False
False
Display the status of the input signal or output signal (True:
High, False: Low).
LineSource
Low
High
Frame Trigger Wait
Frame Active
Exposure Active
FVAL
LVAL
Pulse Generator 0 ~ 3
User Output 0 ~ 3
Line5-OptoIn1
Line6-OptoIn2
Line7 - CC1
Nand 0 Out
Nand 1 Out
Low
Select the line source signal for the item selected in Line
Selector.
Line Format
NoConnect
TTL
OptoCoupled
InternalSignal
-
Display the current I/F type.
LineStatusAll
-
-
Display the input/output signal status.