AP-1600T-PMCL | AP-3200T-PMCL | User Manual (Ver. 2.0)
Main Functions
- 71 -
Trigger Sequencer mode
With this mode, the Sequencer Trigger “pattern” is predetermined by the user. The user defines up to
128 different “indexes.” The items indicated in the above index can be configured for each index. The
operation of this mode is controlled using the following commands.
l
SequencerSetActive
: This allows you to confirm the currently configured index number.
l
SequencerSetStart
: This configures the index number to execute at the start of
TriggerSequencer mode.
l
SequencerLUTMode
: This defines whether to apply gamma or LUT to the sequence. When
gamma is selected, the gamma setting defined in AnalogControl is applied to all exposures in the
sequence. When LUT is selected, the LUT characteristics defined in AnalogControl are applied
to indexes for which SequencerLUT enable is set to ON.
l
SequencerReset
: During TriggerSequencer mode operation, this switches the index number to
be executed to.
Sample TriggerSequencer mode operation
User-defined Indexes (up to 128)
1. Specify "1" in SequencerSetStart, and start TriggerSequencer mode with index 1.
2. Capture a 2-frame image with the first and second triggers.
3. For the next index, configure index 3 specified in SequencerSetNext, and capture an image with
the number of frames (number of triggers) specified in SequencerFrameNumber. Proceed to
sequence from index 4 to index 2 to index 1.