AP-1600T-PMCL | AP-3200T-PMCL | User Manual (Ver. 2.0)
Short ASCII Command List
- 115 -
Name
Access
Short
ASCII
Values
Default
Description
CounterReset
[CounterSelector]
Counter1 (ExposureStart)
W/O
CR1
0
-
CR1=[Param.]<CR><LF>
CounterEventSource != Off:
Counter1 -> Reset to 0, and
continue to count.
CounterEventSource = Off:
Counter1 -> Reset to 0.
CounterReset
[CounterSelector]
Counter2 (SensorReadout)
W/O
CR2
0
-
CR2=[Param.]<CR><LF>
CounterEventSource != Off:
Counter2 -> Reset to 0, and
continue to count.
CounterEventSource = Off:
Counter2 -> Reset to 0.
CounterValue
[CounterSelector]
Counter0
R/O
CV0
0 ~ 65535
0
CV0?<CR><LF>
CounterValue
[CounterSelector]
Counter1
R/O
CV1
0 ~ 65535
0
CV1?<CR><LF>
CounterValue
[CounterSelector]
Counter2
R/O
CV2
0 ~ 65535
0
CV2?<CR><LF>
User Set Control (Command List)
Note:
For more information on each setting, see
(Setting List).
Name
Access
Short
ASCII
Values
Default
Description
UserSetLoad
R/W
LD
0: Default
1: UserSet1
2: UserSet2
3: UserSet3
0
LD=[Param.]<CR><LF>
LD?<CR><LF>
UserSetSave
W/O
SA
1: UserSet1
2: UserSet2
3: UserSet3
1
SA=[Param.]<CR><LF>