background image

Technical Specifications

Item no. 10204051, Revision 02

15 ( 36 )

Measured values: S2-Pmax./5 s

Rated rotation speed

10.000

15.000

20.000

25.000

30.000

40.000

50.000

rpm

Speed

7.345

13.199

18.298

23.530

28.820

38.910

47.917

rpm

Frequency

333

500

667

833

1.000

1.333

1.667

Hz

Rated power

0,828

1,469

2,035

2,598

3,164

4,031

5,2

kW

Torque

1,08

1,06

1,06

1,05

1,05

0,99

1,04

Nm

Voltage

76

116

155

196

238

311

330

V

Current

15

14

15

15

16

15

15

A

Cos φ

0,87

0,81

0,76

0,72

0,69

0,66

0,77

Note on operation with static frequency converters:

For  operation  with  a  frequency  converter,  the  effective  fundamental  voltage
must correspond to the specified motor voltage.

The  measured  currents  may  be  greater  than  the  specified  values  due  to  the
harmonic content.

6.2.1

Performance Diagram

Summary of Contents for Z80-M450.06 S5V

Page 1: ...Manual Z80 M450 06 S5V High Frequency Spindle Manual taper change...

Page 2: ...velopment we reserve the right to make technical modifications and variations from the exact design described in the manual The text in this manual has been compiled with the utmost care However Nakan...

Page 3: ...r MiniCoder 19 6 5 1 Technical Specifications 19 6 6 Air borne noise emissions 20 7 Operating location 20 8 Installation 21 8 1 Installing the HF spindle 21 8 2 Diameter of media supply line 22 8 3 Co...

Page 4: ...of the man ual carefully again 1 2 Explanation of symbols used To enable quick classification of information this manual uses visual aids in the form of symbols and text markings Notes are marked with...

Page 5: ...ories Available on request q Spindle holder q Frequency converter q Chiller q Collet grease q Further accessories on request Only approved accessories have been tested for operational safety and func...

Page 6: ...nd a frequency con verter 3 1 Permissible types of machining The HF spindle has been developed only for the following types of machining q Cutting q Drilling q Engraving q Grinding Contact Nakanishi J...

Page 7: ...re not approved for use in areas at risk of explosion Use in such areas may result in explosions u Do not use the HF spindle in potentially explosive atmospheres DANGER Due to flying parts The HF spin...

Page 8: ...ay cause chips to fly out with great force u Never remove the protective devices of the machine or system u Always wear protective goggles during work Example of design Inserting the shank Note Ensure...

Page 9: ...the machine controller for evaluation 4 3 Installation and maintenance Carry out installation cleaning and maintenance work only after shutting down the HF spindle and after the shaft has come to a s...

Page 10: ...10204051 Revision 02 10 36 5 Technical description 5 1 Connections of HF spindle 1b 2 2 3 1a 1a Electrical connection for motor phases 1b Electrical connection for Tool taper monitoring 2 Cooling wat...

Page 11: ...the machine con troller Note Connect the SpeedTEC quick locking connector u For the combination SpeedTEC connector plug SpeedTEC cable plug u Remove the O ring on the SpeedTEC connector plug 5 3 Cooli...

Page 12: ...y 1 667 Hz Motor poles pairs 2 Rated rotation speed 50 000 rpm Acceleration braking value Per second 10 000 rpm other values by consultation Characteristics Speed sensor Vector control Toothed wheel T...

Page 13: ...Technical Specifications Item no 10204051 Revision 02 13 36 Inner taper run out 1 Axial run out 1 6 1 Dimensions Clamping range...

Page 14: ...00 rpm Speed 8 261 13 327 18 709 23 734 28 983 39 155 48 179 rpm Frequency 333 500 667 833 1 000 1 333 1 667 Hz Rated power 0 6 1 014 1 345 1 659 1 909 2 408 2 741 kW Torque 0 69 0 73 0 69 0 68 0 63 0...

Page 15: ...28 1 469 2 035 2 598 3 164 4 031 5 2 kW Torque 1 08 1 06 1 06 1 05 1 05 0 99 1 04 Nm Voltage 76 116 155 196 238 311 330 V Current 15 14 15 15 16 15 15 A Cos 0 87 0 81 0 76 0 72 0 69 0 66 0 77 Note on...

Page 16: ...Stator Stator U DFP Digitale Feldplatte Differential magneto resistor 0 75 mm 0 14 mm 0 14 mm U V W PIN 3 7 4 pole 4 7 2 pole 2 7 2 pole 2 4 2 pole 3 7 2 pole AC 7 01 2 PTC PTC AC 8 01 4 C B A G blau...

Page 17: ...mm wird nicht ben tigt isoliert hineinlegen not connected isolated YE 0 25 mm BK 0 25 mm WH 0 25 mm BN 0 25 mm GY 0 25 mm BU 0 25 mm RD 0 25 mm PK 0 25 mm 2 0 1 Perschewski 16 03 17 1 29022570 g f e...

Page 18: ...cording to the positive temperature coefficient thermistor temperature TPTC small signal resistance Technical Specifications Type M135 Max operating voltage TA 0 40 C V max 30 V Max measuring voltage...

Page 19: ...nical Specifications Output level 1 VSS as differential signal Output signal 2 sinusoidal signals offset by 90 and their inverse signals short circuit proof Option reference pulse Output frequency 0 2...

Page 20: ...G Risk of injury due to flying parts The HF spindle operates at high speeds which may cause chips to fly out with great force u Never remove the protective devices of the machine or system u Always we...

Page 21: ...e and free of strain Seal all connections for compressed air axially in relation to the tightening direction Seal all connections for cooling water axially in relation to the tightening direction If t...

Page 22: ...s immediate corrosion on bare parts which is often unno ticeable at first but later leads to serious corrosion damage Do not use pure or distilled water Deposits in cooling channels due to unsuitable...

Page 23: ...n air quality see Air purity classes ISO 8573 1 23 section The adjustment value for the sealing air depends on the hose diameter and length Hose diameter DN 4 The setting value can be found in the fol...

Page 24: ...the centrifugal forces q The clamping system is shifted q The balance of the HF spindle is affected q The bearing is damaged Turn the shaft of the spindle at least ten times by hand Before storing an...

Page 25: ...rding this to the machine controller for evaluation 9 4 Commissioning after storage Do not put the HF spindle into operation until its temperature has adjusted from the temperature of the storage loca...

Page 26: ...F spindle is affected q The bearing is damaged 10 1 Clockwise and counter clockwise Sample illustration Direction of rotation indication The HF spindle clamping system is designed for clockwise and co...

Page 27: ...service set Insert the tool taper into the HF spindle See figure Joining position Insert the hexagon wrench into the threaded spindle through the access hole Tighten the threaded spindle clockwise wit...

Page 28: ...ments may be flung out u Note the maximum speed for the selected tool u Note the maximum speed for the HF spindle u The maximum permissible speed of the HF spindle for commissioning processing is alwa...

Page 29: ...to the openings of the HF spindle 12 2 Daily cleaning To ensure that the HF spindle functions safely and accurately all contact sur faces of the HF spindle the mount for the HF spindle the tool mount...

Page 30: ...zontal position Store the HF spindle so that it is protected from moisture dust and other environmental influences Note the following storage conditions Temperature of storage location 10 C 45 C Relat...

Page 31: ...n More than 90 of the materials used in the HF spindle can be recycled alu minum stainless steel steel copper etc The HF spindle may not be disposed of with normal domestic waste Remove all non recycl...

Page 32: ...energy supply companies u Before commencing work switch off the power supply of the HF spindle Note Damage due to electrostatic discharge Do not touch the electrostatic sensitive components of the HF...

Page 33: ...er See also Spindle becomes hot 33 Frequency converter has shut down q Check the error messages in the frequency converter man ual HF spindle becomes hot Cause Troubleshooting Insufficient cooling q C...

Page 34: ...HF spindle vibrates oscillates Cause Troubleshooting Tool unsuitable q Only use balanced tools Also see the Tools for high speed cutting 28 section q Check whether the tool is suitable for the applica...

Page 35: ...1 5 6 1 5 8 1 5 9 1 6 4 1 6 5 1 7 1 1 7 1 1 1 7 2 1 7 3 1 7 4 The incomplete machinery in its standard design complies furthermore with the following applicable regulations Applicable harmonized stan...

Page 36: ...rlen GERMANY 49 0 6002 9123 0 sales anakanishi jaeger com www nakanishi jaeger com Serial number Type Z80 M450 06 S5V Item no 10204051 Revision 02 Date 01 09 2023 Language EN Jaeger Spindles North Ame...

Reviews: