background image

Dismantling

Item no. 10301165, Revision 01

34 ( 40 )

13

Dismantling

Proceed as follows to remove the HF spindle:

Ü

Completely disconnect the power supply.

Ü

Completely disconnect the media supply (air and liquid).

Ü

Make sure that the shaft of the HF spindle has come to an absolute stand-
still.

Ü

Remove all connections from the HF spindle.

Ü

Remove the HF spindle from the machine.

13.1

Disposal and environmental protection

More than 90% of the materials used in the HF spindle can be recycled (alu-
minum, stainless steel, steel, copper, etc.)

The HF spindle may not be disposed of with normal domestic waste.

Ü

Remove all non-recyclable materials.

Ü

Dispose of the HF spindle as scrap at an approved recycling facility.

Ü

Follow all rules of the responsible administrative bodies.

If  the  HF  spindle  cannot  be  dismantled,  send  the  HF  spindle  to 

Nakanishi

Jaeger GmbH

Nakanishi Jaeger GmbH 

shall not assume the costs incurred

for shipment and the fees for the recycling facilities.

Summary of Contents for Z42-D160.20 S2A

Page 1: ...Manual Z42 D160 20 S2A High Frequency Spindle Pneumatic direct change...

Page 2: ...opment we reserve the right to make technical modifications and variations from the exact design described in the manual The text in this manual has been compiled with the utmost care However Nakanish...

Page 3: ...tial magneto resistor 20 6 6 ESD protection 20 6 7 Air borne noise emissions 21 7 Operating location 22 8 Installation 23 8 1 Installing the HF spindle 23 8 2 Diameter of media supply line 23 8 3 Comp...

Page 4: ...Contents Item no 10301165 Revision 01 4 40...

Page 5: ...of the man ual carefully again 1 2 Explanation of symbols used To enable quick classification of information this manual uses visual aids in the form of symbols and text markings Notes are marked with...

Page 6: ...s the service life of the HF spindle 2 1 Scope of supply of HF spindle The following parts are supplied with the HF spindle q High Frequency Spindle q Collet q Service set q Transport packaging Check...

Page 7: ...th the Machinery Directive and cannot perform any function independently The HF spindle can only be operated in conjunction with a machine tool and a frequency con verter 3 1 Permissible types of mach...

Page 8: ...re not approved for use in areas at risk of explosion Use in such areas may result in explosions u Do not use the HF spindle in potentially explosive atmospheres DANGER Due to flying parts The HF spin...

Page 9: ...ause chips to fly out with great force u Never remove the protective devices of the machine or system u Always wear protective goggles during work Example of design Inserting the shank Note Ensure fun...

Page 10: ...o the machine controller for evaluation 4 3 Installation and maintenance Carry out installation cleaning and maintenance work only after shutting down the HF spindle and after the shaft has come to a...

Page 11: ...erter FC Check whether the current voltage and frequency data of the HF spindle match the raw data for the frequency converter Use a motor supply line that is as short as possible Adjust the speed of...

Page 12: ...via spindle holder Example of design Air cooled spindle holder Example of design Liquid cooled spindle holder To increase the power of the HF spindle the heat generated must be dissi pated via the sp...

Page 13: ...ips and liquids from entering the shaft during a tool change and causing contamination and damage to the inner taper and the clamping system The taper cleaning is integrated in the pneumatics system f...

Page 14: ...1 Rated rotation speed 60 000 rpm Acceleration braking value Per second 10 000 rpm other values by consultation Characteristics Speed sensor Differential magneto resistor TTL Number of signals 6 Moto...

Page 15: ...Technical Specifications Item no 10301165 Revision 01 15 40 Weight 2 2 kg Inner taper run out 1 6 1 Dimensions Clamping range...

Page 16: ...ted rotation speed 10 000 20 000 30 000 40 000 50 000 60 000 rpm Speed 7 334 18 334 27 410 36 704 45 936 55 250 rpm Frequency 167 333 500 667 833 1 000 Hz Rated power 0 059 0 163 0 247 0 240 0 278 0 3...

Page 17: ...0 182 0 413 0 57 0 718 0 835 kW Torque 0 127 0 092 0 141 0 146 0 147 0 141 Nm Voltage 20 44 60 71 82 93 V Current 6 7 8 3 8 4 7 9 8 8 3 A Cos 0 9 0 61 0 74 0 82 0 85 0 84 Note on operation with stati...

Page 18: ...see chart DFP Feldplatte DMR Drehzahlgrenze Speed limit U hh mm W Z hler Counter U V W PIN PTC PTC 3 7 4 pole 4 7 2 pole 2 7 2 pole 2 4 2 pole 3 7 2 pole AC 7 01 2 blau 0 14mm blue 0 14mm blau 0 14mm...

Page 19: ...cording to the positive temperature coefficient thermistor temperature TPTC small signal resistance Technical Specifications Type M135 Max operating voltage TA 0 40 C V max 30 V Max measuring voltage...

Page 20: ...ground Supply voltage U Rx Signal 8 V 220 1000 mV 8 V 450 2000 mV 12 V 220 1000 mV 12 V 680 3000 mV 15 V 220 1000 mV 15 V 680 3000 mV 24 V 220 1000 mV 24 V 680 3000 mV Unnecessary if a resistor is in...

Page 21: ...Technical Specifications Item no 10301165 Revision 01 21 40 6 7 Air borne noise emissions CAUTION Noise has an impact on health u Only operate the HF spindle if you are wearing hearing protection...

Page 22: ...speeds which may cause chips to fly out with great force u Never remove the protective devices of the machine or system u Always wear protective goggles during work Example of design Mounting surface...

Page 23: ...xible and free of strain Seal all connections for compressed air axially in relation to the tightening direction If the HF spindle is equipped with sealing air Make sure that no air flow can occur in...

Page 24: ...n air quality see Air purity classes ISO 8573 1 24 section The adjustment value for the sealing air depends on the hose diameter and length Hose diameter DN 4 The setting value can be found in the fol...

Page 25: ...ation Item no 10301165 Revision 01 25 40 8 3 3 Setting values For guidelines on air quality see Air purity classes ISO 8573 1 24 section Keep to the following values Pneumatic system for tool change 6...

Page 26: ...clamping system is damaged by the centrifugal forces q The clamping system is shifted q The balance of the HF spindle is affected q The bearing is damaged Example of design Clockwise Turn the shaft o...

Page 27: ...rding this to the machine controller for evaluation 9 4 Commissioning after storage Do not put the HF spindle into operation until its temperature has adjusted from the temperature of the storage loca...

Page 28: ...ion Only use tools with the correct direction of rotation for the HF spindle Only use tool mounts with the correct HF spindle direction of rotation Set the direction of rotation of the HF spindle on t...

Page 29: ...on occurs during cleaning Clean the inner taper of the shaft with the felt cone from the service set Clean the collet with the brush Apply a light greasy film to the taper of the collet To do this onl...

Page 30: ...llet out of the shaft The collet opens Only the tool is deposited in the changing station Tip Fast tool change u Use a tool with a stop ring This means that there is no need to re adjust the immersion...

Page 31: ...nically sound Only use tools with a tool shank diameter that corresponds to the inner di ameter of the collet For example do not use shanks with a diameter of 3 mm in collets for 1 8 3 175 mm Also see...

Page 32: ...to the openings of the HF spindle 12 2 Daily cleaning To ensure that the HF spindle functions safely and accurately all contact sur faces of the HF spindle the mount for the HF spindle the tool mount...

Page 33: ...ed from moisture dust and other environmental influences Note the following storage conditions Temperature of storage location 10 C 45 C Relative humidity 50 12 4 Monthly maintenance Turn the shaft of...

Page 34: ...sal and environmental protection More than 90 of the materials used in the HF spindle can be recycled alu minum stainless steel steel copper etc The HF spindle may not be disposed of with normal domes...

Page 35: ...energy supply companies u Before commencing work switch off the power supply of the HF spindle Note Damage due to electrostatic discharge Do not touch the electrostatic sensitive components of the HF...

Page 36: ...equency converter has shut down q Check the error messages in the frequency converter man ual Tool change initiated q Turn off the pneumatic system for the tool change HF spindle becomes hot Cause Tro...

Page 37: ...crews of the spindle holder manually q Do not use technical aids to clamp the HF spindle Bearings damaged q Contact Nakanishi Jaeger GmbH service No automatic tool change Cause Troubleshooting Contami...

Page 38: ...serve all points in the Tool change 28 and Mainte nance 32 sections Frequency converter incorrectly set q Compare the values for the HF spindle with the set values on the frequency converter Machining...

Page 39: ...1 5 6 1 5 8 1 5 9 1 6 4 1 6 5 1 7 1 1 7 1 1 1 7 2 1 7 3 1 7 4 The incomplete machinery in its standard design complies furthermore with the following applicable regulations Applicable harmonized stan...

Page 40: ...rlen GERMANY 49 0 6002 9123 0 sales anakanishi jaeger com www nakanishi jaeger com Serial number Type Z42 D160 20 S2A Item no 10301165 Revision 01 Date 01 09 2023 Language EN Jaeger Spindles North Ame...