Jäger Z100-H636.05 S11W2V Manual Download Page 23

Technical Specifications

Item no. 10406024, Revision 00

23 ( 48 )

6.4

Motor protection Pt1000

2-wire connection

Platinum temperature sensor 

Design according to:

q

DIN EN 60751

q

Accuracy class B

Technical Specifications

Temperature/resistance correlation (series of basic values)

Resistance R/ohm

Temperature t/°C

t

90

/°C

(*) Resistance at temperature t

90

/°C [Ω]

0

1

2

3

4

5

6

7

8

9

0

1000

1004

1008

1012

1016

1020

1023

1027

1031

1035

10

1039

1043

1047

1051

1055

1059

1062

1066

1070

1074

20

1078

1082

1086

1090

1094

1097

1101

1105

1109

1113

30

1117

1121

1125

1128

1132

1136

1140

1144

1148

1152

40

1155

1159

1163

1167

1171

1175

1179

1182

1186

1190

50

1194

1198

1202

1206

1209

1213

1217

1221

1225

1229

60

1232

1236

1240

1244

1248

1252

1255

1259

1263

1267

70

1271

1275

1278

1282

1286

1290

1294

1298

1301

1305

80

1309

1313

1317

1320

1324

1328

1332

1336

1340

1343

90

1347

1351

1355

1359

1362

1366

1370

1374

1378

1381

100

1385

1389

1393

1396

1400

1404

1408

1412

1415

1419

110

1423

1427

1431

1434

1438

1442

1446

1449

1453

1457

120

1461

1464

1468

1472

1476

1480

1483

1487

1491

1495

130

1498

1502

1506

1510

1513

1517

1521

1525

1528

1532

140

1536

1540

1543

1547

1551

1555

1558

1562

1566

1570

150

1573

1577

1581

1585

1588

1592

1596

1599

1603

1607

160

1611

1614

1618

1622

1625

1629

1633

1637

1640

1644

170

1648

1651

1655

1659

1663

1666

1670

1674

1677

1681

180

1685

1689

1692

1696

1700

1703

1707

1711

1714

1718

(*) Rounded values

Summary of Contents for Z100-H636.05 S11W2V

Page 1: ...Manual Z100 H636 05 S11W2V High Frequency Spindle Pneumatic taper change ...

Page 2: ...evelopment we reserve the right to make technical modifications and variations from the exact design described in the manual The text in this manual has been compiled with the utmost care However Al fred Jäger GmbH cannot assume any legal responsibility or liability of any kind for incorrect information and any consequences thereof Translations and reproductions including of extracts are prohibite...

Page 3: ...5 6 7 1 Technical Specifications 25 6 8 Air borne noise emissions 26 7 Operating location 27 8 Installation 28 8 1 Installing the HF spindle 28 8 2 Diameter of media supply line 29 8 3 Cooling water 29 8 3 1 Quality of cooling water 29 8 3 2 Setting the cooling 29 8 4 Compressed air 30 8 4 1 Air purity classes ISO 8573 1 30 8 4 2 Setting the sealing air 30 8 4 3 Setting values 31 9 Commissioning 3...

Page 4: ...24 Revision 00 4 48 Contents Translation of the original manual 13 1 Disposal and environmental protection 42 14 Service and repairs 43 14 1 Service partners 43 14 2 Malfunctions 44 15 Declaration of Incorporation 47 ...

Page 5: ...tion of the man ual carefully again 1 2 Explanation of symbols used To enable quick classification of information this manual uses visual aids in the form of symbols and text markings Notes are marked with a signal word and a colored box DANGER Dangerous situation Results in serious injury or death u Measure to avert the danger WARNING Dangerous situation May result in serious injury or death u Me...

Page 6: ...ccessories Available on request q Spindle holder q Frequency converter q Chiller q Collet grease q Further accessories on request Only approved accessories have been tested for operational safety and func tionality Ü Do not use any other accessories this may invalidate any warranty claims and compensation claims for damages Ü If the spindle holder is to be produced in house it is essential to cont...

Page 7: ...l and a frequency con verter 3 1 Permissible types of machining The HF spindle has been developed only for the following types of machining q Cutting q Drilling q Engraving q Grinding Ü Contact Alfred Jäger GmbH if other types of machining are required 3 2 Permissible materials The HF spindle has been developed only for the following materials q Metals such as alloys cast metals etc q Sintered mat...

Page 8: ...are not approved for use in areas at risk of explosion Use in such areas may result in explosions u Do not use the HF spindle in potentially explosive atmospheres DANGER Due to flying parts The HF spindle operates at high speeds and may therefore be flung away by these u Operate the HF spindle only if it is installed in the machine or system in a fixed manner Note Adhere to the limit values u Obse...

Page 9: ...use chips to fly out with great force u Never remove the protective devices of the machine or system u Always wear protective goggles during work Example of design Inserting the shank Note Ensure functionality u Never operate the HF spindle without a clamped tool shank If no tool shank is clamped q The clamping system is damaged by the centrifugal forces q The clamping system is shifted q The bala...

Page 10: ...nd forwarding this to the machine controller for evaluation 4 3 Installation and maintenance Ü Carry out installation cleaning and maintenance work only after shutting down the HF spindle and after the shaft has come to a standstill Ü Install all safety and protective devices of the machine immediately after completing work 4 4 Modification and repair Modifications or alterations to the HF spindle...

Page 11: ... 4 1c 2 2 1a Electrical connection for motor phases 1b Electrical connection for Tool taper monitoring PTC Pt1000 1c Electrical connection for Vector control 2 Cooling water G 1 4 3 Sealing air G 1 8 4 Taper cleaning G 1 8 7 Pneumatics for tool change cylinder forward G 1 8 8 Pneumatics for tool change cylinder back G 1 8 ...

Page 12: ...r information The FC detects the following operating states of the HF spindle depending on the version q HF spindle rotating q HF spindle too hot q HF spindle at a standstill etc The FC forwards the operating states of the HF spindle to the machine con troller 5 3 Cooling Liquid cooling keeps the HF spindle at a constant temperature during opera tion Note Extension of the service life through heat...

Page 13: ... spindle 5 5 Taper cleaning For guidelines on air quality see Air purity classes ISO 8573 1 30 section Taper cleaning prevents chips and liquids from entering the shaft during a tool change and causing contamination and damage to the inner taper and the clamping system 5 6 Pneumatic tool change For guidelines on air quality see Air purity classes ISO 8573 1 30 section The tool change or tool taper...

Page 14: ...Hz Motor poles pairs 2 Rated rotation speed 36 000 rpm Acceleration braking value Per second 10 000 rpm other values by consultation Characteristics Speed sensor Vector control Toothed wheel Teeth 150 Module 0 3 Motor protection PTC 150 C Pt1000 Housing Stainless steel Housing diameter 100 mm Cooling Liquid cooled Ambient temperature 10 C 45 C Sealing air Protection category sealing air turned on ...

Page 15: ...al Specifications Item no 10406024 Revision 00 15 48 Coupler plug 5 pin ECTA 133 motor phases 12 pin ECTA 133 17 pin sensors Weight 15 kg Inner taper run out 1 µ Axial run out 1 µ 6 1 Dimensions Clamping range ...

Page 16: ...00 20 000 25 000 30 000 36 000 rpm Speed 4 185 9 242 14 271 19 299 24 328 29 191 35 062 rpm Frequency 167 333 500 667 833 1 000 1 200 Hz Rated power 1 898 4 546 6 6 8 5 10 014 9 944 9 548 kW Torque 4 332 4 698 4 442 4 187 3 931 3 253 2 695 Nm Voltage 89 170 240 310 380 380 380 V Current 24 8 25 7 24 8 23 9 23 1 22 6 21 7 A cos φ 0 84 0 8 0 79 0 78 0 77 0 79 0 79 Measured values S6 60 Rated rotatio...

Page 17: ... 01 15 281 kW Torque 6 12 6 846 6 712 6 579 6 445 5 341 4 41 Nm Voltage 89 170 240 310 380 380 380 V Current 38 38 38 38 38 38 4 38 2 A cos φ 0 90 0 84 0 82 0 81 0 79 0 79 0 77 Note on operation with static frequency converters For operation with a frequency converter the effective fundamental voltage must correspond to the specified motor voltage The measured currents may be greater than the spec...

Page 18: ...s p0322 Maximum speed 42 000 rpm p0326 Stalling torque correction factor 100 p0335 Cooling type Liquid cooled p0341 Moment of inertia 0 0011 kgm p0348 Field weakening operating speed VDC 600V 60 178 rpm p0350 Stator resistance cold strand 0 225 Ω p0353 Series inductance strand 0 mH p0354 Rotor resistance cold 0 243 Ω p0356 Stator stray inductance 0 365 mH p0358 Rotor stray inductance 0 352 mH p036...

Page 19: ...em no 10406024 Revision 00 19 48 Parameter Meaning Value Unit Desaturation speed 40 082 rpm Main inductance at maximum speed 4 472 mH Saturation factor 1 187 Tilting torque reduction factor 58 09 Additional parameters Heidenhain ...

Page 20: ...er Fa Alfred Jäger GmbH untersagt Datum Gepr Bearb Norm Projekt Nr Version Nr Zeichn Nr von Blatt DIN 81346 Pinbelegung FS5 S11 ECTA Gerätestecker FS5 S11 spindle plug FS5 S11 Spindel U V W GNYE 0 2mm BK 0 2mm BU 0 2mm BN 0 2mm Stator 1 2 3 PE 4 BN RD RD BN BU GN BU VT BK WH WH WH gn ge 2 5 mm AC 6 01 2 AC 7 01 2 AC 8 01 4 8 2 11 4pol 8 1 11 4pol 3 7 4pol 4 7 2pol 2 7 2pol Motorvarianten Kundensei...

Page 21: ... BK BU 3 4 PNP Spindelstecker S12 ECTA S13 spindle plug S12 ECTA S13 BN 1 Vs output 0V BK BU 3 4 PNP BN 1 Vs output 0V BK BU 3 4 PNP C RD BN 0 25mm WH WH 0 25mm BN 0 14mm BU 0 14mm BK 0 14mm BK 0 14mm BK 0 14mm PTC BU 0 14mm RD 0 14mm PNP Induktiver Näherungsschalter Inductive proximility switch 1 Perschewski 09 04 18 1 PTC KTY WK 29030070 g f e d c b a 4 5 6 1 3 2 a b c d e f g Bl Übersetzungen V...

Page 22: ...Perschewski 16 03 17 1 29022570 g f e d c b a 4 5 6 1 3 2 a b c d e f g Bl Übersetzungen Vervielfältigungen und die Weitergabe an Dritte auch nur auszugsweise ist ohne schriftliche Gehnehmigung der Fa Alfred Jäger GmbH untersagt Datum Gepr Bearb Norm Projekt Nr Version Nr Zeichn Nr von Blatt DIN 61346 Flanschstecker FS17 S10 GN 0 25 mm wird nicht benötigt isoliert hineinlegen not connected isolate...

Page 23: ...7 1171 1175 1179 1182 1186 1190 50 1194 1198 1202 1206 1209 1213 1217 1221 1225 1229 60 1232 1236 1240 1244 1248 1252 1255 1259 1263 1267 70 1271 1275 1278 1282 1286 1290 1294 1298 1301 1305 80 1309 1313 1317 1320 1324 1328 1332 1336 1340 1343 90 1347 1351 1355 1359 1362 1366 1370 1374 1378 1381 100 1385 1389 1393 1396 1400 1404 1408 1412 1415 1419 110 1423 1427 1431 1434 1438 1442 1446 1449 1453 ...

Page 24: ... voltage Vis 3 kV Response time ta 2 5 s Operating temperature range V 0 Top 25 180 C Resistance values TNAT ΔT R TNAT ΔT VPTC 2 5 V R TNAT ΔT VPTC 2 5 V R TNAT 15 K VPTC 7 5 V R TNAT 23 K VPTC 2 5 V 150 5 C 550 Ω 1330 Ω 4 kΩ 6 6 Tool change monitoring Tool taper monitoring indicates the readiness status of the HF spindle to the operator and forwards the corresponding signal to the machine control...

Page 25: ...hnical Specifications Output level 1 VSS as differential signal Output signal 2 sinusoidal signals offset by 90 and their inverse signals short circuit proof Option reference pulse Output frequency 0 200 kHz for a line capacity of 5 nF Offset static 20 mV Amplitude tolerance 20 10 Amplitude synchronization USp1 USp2 0 9 1 1 Supply voltage UB 5 VDC 5 Power consumption without load 0 3 W Cable lengt...

Page 26: ...Technical Specifications Item no 10406024 Revision 00 26 48 6 8 Air borne noise emissions CAUTION Noise has an impact on health u Only operate the HF spindle if you are wearing hearing protection ...

Page 27: ...eds which may cause chips to fly out with great force u Never remove the protective devices of the machine or system u Always wear protective goggles during work Example of design Mounting surface Note the following points before installing the HF spindle Ü Make sure that the correct spindle holder for the HF spindle is fitted in the machine Ü Check the connecting hoses for damage Ü Check the conn...

Page 28: ...esponding hoses in the hose fittings Ü Make sure that the connections are flexible and free of strain Ü Seal all connections for compressed air axially in relation to the tightening direction Ü Seal all connections for cooling water axially in relation to the tightening direction Ü If the HF spindle is equipped with sealing air Ä Make sure that no air flow can occur in the bearing area Ä Always us...

Page 29: ... immediate corrosion on bare parts which is often unno ticeable at first but later leads to serious corrosion damage Ü Do not use pure or distilled water Deposits in cooling channels due to unsuitable cooling water prevent the dis sipation of heat Ü Use cooling water with the following properties Drinking water according to 98 83 EC Hardness 1 15 dH PH value 7 9 Additive corrosion protection 20 An...

Page 30: ... air quality see Air purity classes ISO 8573 1 30 section The adjustment value for the sealing air depends on the hose diameter and length Ü Hose diameter DN 4 Ü The setting value can be found in the following diagram Ü To ensure effective control turn on the sealing air and cooling when turn ing on the machine This protects the HF spindle even when it is stationary Lowest sealing air supply Dry m...

Page 31: ...o 10406024 Revision 00 31 48 8 4 3 Setting values For guidelines on air quality see Air purity classes ISO 8573 1 30 section Ü Keep to the following values Taper cleaning 4 5 6 bar Pneumatic system for tool change 6 0 bar ...

Page 32: ...entrifugal forces q The clamping system is shifted q The balance of the HF spindle is affected q The bearing is damaged Ü Turn the shaft of the spindle at least ten times by hand Ü Before storing and before commissioning only clean the cooling duct with compressed air 9 1 Running in schedule Duration of load minutes Max load Ü Put the HF spindle into operation with a clamped tool without machining...

Page 33: ...ing this to the machine controller for evaluation 9 4 Commissioning after storage Ü Do not put the HF spindle into operation until its temperature has adjusted from the temperature of the storage location to the temperature of the us age location Ä The temperature difference between the HF spindle and the usage lo cation should not exceed 10 C Ü Carry out all steps in the Maintenance 40 section Ü ...

Page 34: ...The clamping system is damaged by the centrifugal forces q The clamping system is shifted q The balance of the HF spindle is affected q The bearing is damaged 10 1 Clockwise and counter clockwise Sample illustration Direction of rotation indication The HF spindle clamping system is designed for clockwise and counter clock wise rotation Ü Only use tools with the correct direction of rotation for th...

Page 35: ...age and clean when switching to the HF spindle Insert the tool up to the contact surface of the clamping taper Ü Make sure that the shaft of the HF spindle has come to an absolute stand still Ü Switch on the compressed air for cylinder forward Ü Remove the tool Ü Clean the inner taper of the tool mount and the inner taper of the shaft with the felt cleaning taper Ü Insert the tool Ä Insert the too...

Page 36: ...ic taper change During a tool change the tool mount is pressed out of the shaft by the cylin der 10 3 2 Installing the changing station Proceed as follows to install the changing station Ü Drill a hole with a suitable diameter Ø D1 H7 for the tool mount Ü Add an M5 thread Ü Insert the changing station into the hole Ü Secure the changing station using the threaded spindle M5 10 3 3 Maintenance Befo...

Page 37: ... Tool change at the HF spindle Caution No rotation without clamped tool Tool clamped signal HF spindle is ready for use No Connection on off Compressed air Always leave sealing air switched on Even in the case of a tool change This prevents dirt or moisture from entering the HF spindle 3 Taper cleaning on 4 Pneumatic system for tool change on Cylinder forward 7 Perform tool change Taper cleaning o...

Page 38: ...rt HF spindle Clamped signal Cylinder back Clamping system clamped with tool Tool taper inserted in tool mount of HF spindle 1 Start HF spindle when signal 1 Ejected signal Cylinder is extended Clamping system disengaged Tool taper inserted in tool mount of HF spindle Tool taper is not clamped here 0 Do not start HF spindle Note Ensure functionality The released signal shows the user the ready sta...

Page 39: ...may be flung out u Note the maximum speed for the selected tool u Note the maximum speed for the HF spindle u The maximum permissible speed of the HF spindle for commissioning processing is always the lowest specified speed Ü Only use tools that are technically sound Ü Only use tools with a tool shank diameter that corresponds to the inner di ameter of the collet For example do not use shanks with...

Page 40: ...ensure that the HF spindle functions safely and accurately all contact sur faces of the HF spindle the mount for the HF spindle the tool mount and the tool holder must be clean Note Foreign matter reduces the service life u Do not use compressed air to clean the HF spindle u Do not use ultrasonic cleaning on the HF spindle u Do not use steam jets to clean the HF spindle This could cause contaminat...

Page 41: ...ve all coolant residues Ü Store the HF spindle in horizontal position Ü Store the HF spindle so that it is protected from moisture dust and other environmental influences Ü Note the following storage conditions Temperature of storage location 10 C 45 C Relative humidity 50 12 4 Monthly maintenance Ü Turn the shaft of the HF spindle at least ten times by hand every four weeks 12 5 Long periods of s...

Page 42: ...tection More than 90 of the materials used in the HF spindle can be recycled alu minum stainless steel steel copper etc The HF spindle may not be disposed of with normal domestic waste Ü Remove all non recyclable materials Ü Dispose of the HF spindle as scrap at an approved recycling facility Ü Follow all rules of the responsible administrative bodies Ü Do not discharge coolants into wastewater Ü ...

Page 43: ...al energy supply companies u Before commencing work switch off the power supply of the HF spindle Note Damage due to electrostatic discharge Do not touch the electrostatic sensitive components of the HF spindle 14 1 Service partners Only certified service partners may open and repair the spindle Failure to comply with this voids any warranty claims and compensation claims for dam ages Ü The list o...

Page 44: ...requency converter has shut down q Check the error messages in the frequency converter man ual Tool change initiated q Turn off the pneumatic system for the tool change HF spindle becomes hot Cause Troubleshooting Insufficient cooling q Check the power of the chiller q Check the water level of the chiller q Check the connections and the cooling hoses q Check the cooling circuit q Check the chiller...

Page 45: ...e spindle holder manually q Do not use technical aids to clamp the HF spindle Bearings damaged q Contact Alfred Jäger GmbH service No automatic tool change Cause Troubleshooting Contamination q Remove all contamination between the tool taper and shaft of the HF spindle Observe all points in the Tool change 34 and Mainte nance 40 sections Lack of pressure q Check the connections for compressed air ...

Page 46: ...or damage q Replace damaged tool Contamination q Remove all contamination between the tool taper and shaft of the HF spindle Observe all points in the Tool change 34 and Mainte nance 40 sections Frequency converter incorrectly set q Compare the values for the HF spindle with the set values on the frequency converter Machining too heavy q Reduce the machining load intensity Mounting screws are loos...

Page 47: ...1 5 5 1 5 6 1 5 8 1 5 9 1 6 4 1 6 5 1 7 1 1 7 1 1 1 7 2 1 7 3 1 7 4 The incomplete machinery in its standard design complies furthermore with the following applicable regulations Applicable harmonized standards DIN EN ISO 12100 Safety of machines The machinery is incomplete and must not be put into service until the ma chinery into which it is to be incorporated has been declared in conformity wit...

Page 48: ...1239 Ober Mörlen GERMANY 49 0 6002 9123 0 sales alfredjaeger de www alfredjaeger de Serial number Type Z100 H636 05 S11W2V Item no 10406024 Revision 00 Date 01 08 2023 Language EN Jaeger Spindles North America Corp 6611 Bay Circle Suite 165 Norcross GA 30071 USA 1 770 674 4480 office jaegerspindles com www alfredjaeger de en ...

Reviews: