Technical description
Item no. 10302006, Revision 10
11 ( 36 )
5.3
Cooling
Liquid cooling keeps the HF spindle at a constant temperature during opera-
tion.
Note: Extension of the service life through heat dissipation.
Heat is produced during operation of the HF spindle. The temperature of the
HF spindle should not 45° C as this shortens the service life of the
bearing.
u
Check the temperature of the HF spindle on the housing.
5.4
Sealing air
For guidelines on air quality,
see "Air purity classes (ISO
8573-1)
" section.
The sealing air prevents foreign bodies such as chips and liquids (e.g. emul-
sions) from entering the HF spindle.
Ü
Check that air escapes at the front between the housing and the rotating
parts of the HF spindle.
5.5
Pneumatic tool change
For guidelines on air quality,
see "Air purity classes (ISO
8573-1)
" section.
The tool change or tool taper change is performed pneumatically.
During this, a mechanism is operated inside the HF spindle which clamps, re-
leases, or ejects the tool taper or collet.