ATTENTION !!
1.5 m
The room thermostat must be installed at approx.
1.5 m above floor and out of reach of external influ-
ences such as direct sunlight, draught or other heat
sources as they may impede the correct functioning
of the thermostat. Nearby electric fires, televisions,
wall or table lamps may prevent the thermostat from
working properly.
UP
UP
6
2.7
Mount the JRT-300 Room thermostat on a wall re-
cessed box (60.3 mm fixing centers) or direct onto a flat
wall using wall plugs.
Features
• for heating systems
• display with back-light
• programmable Monday to Friday, Saturday, Sunday (5+1+1), 2 programmable
time zones per day
• displays the measured temperature and time
• temperature in °Celsius
• surface-mounting
• with a wall-fixing frame
Technical Data
Operating voltage:
2 x AAA1.5 V, alkaline batteries.
Backup storage:
EEPROM
Max. voltage / (ohm) load:
8 A.
Channel selection:
By programming the thermostat and the receiver.
Switching options:
5+1+1 day, 2 periods each day.
Temperature settings:
5°C ~ 30°C, 0.5°C increments.
Accuracy:
+/- 0.5°C.
Thermostat dimensions:
Surface mounted, 135mm x 87.5 mm x 23.2mm.
Housing:
ABS to UL94-5 fire retardant plastic, white
IP protection rating:
20
Certification:
CE
Product-documentation:
• this manual is an integral part of the unit and must be handed over to the user
after the installation of the device is completed in order to comply with applicable
legal requirements.
• please read the manual carefully so that you understand the information in order
to ensure safety during installation, use and maintenance.
• no liability is accepted for damage resulting from non-compliance with the
guidelines in this installation manual.
Dimensions
SET
PRG
13.5
8.75
8
2.7
11.8
6.2
9.9
2.3
CE-mark
The CE-mark symbolizes the compliance of the device with the following guide-
lines:
• EN 61000-6-3:2007+A1:2011
• EN 61000-3-2:2006+A1:2009+A2:2009
• EN 61000-3-3:2008
• EN 61000-6-1:2007
IMPORTANT: This manual will guide you through the installation, setup and use of the Jaga Room Thermostat JRT-300. Keep this manual in
a safe place for future reference.