Jade Safety & Security Weather Light Series Quick Manual Download Page 1

                         

‘’ 

WEATHER LIGHT ‘’ SERIES FOR NON-MAINTAINED LUMINAIRES

220-240V AC/50-60Hz

4 VA

5.5 VA

5.5 VA

3 VA

Bayblend FR3010

,

 

transparent 

 

polycarbonate

TECHNICAL CHARACTERISTICS

OPERATION TEMPERATURE RANGE
RELATIVE HUMIDITY

EXTERNAL DIMENSIONS 

CONSTRUCTION MATERIALS 

TYPICAL WEIGHT

GUARANTEE 

OPERATION VOLTAGE

MAXIMUM POWER CONSUMPTION
BATTERIES

 (

Ni-Cd

)

CHARGING TIME

INDICATIONS 

CONTROLS

BATTERY PROTECTION

MINIMUM AUTONOMOUS DURATION

DEGREES OF COVER PROTECTION

PRODUCED IN ACCORDANCE WITH

LIGHT SOURCE INTENSITY (emergency)

FLUORESCENT LAMP

3h

3h

3h

90min

90min

24h

Battery charging LED

TEST button

From full discharge

2.4V/1.5Ah

2.4

V/

3

Ah

170lm 

  85lm 

  8W (T5) 

  2x8W (T5) 

EN 60598-1, EN 60598-2-22

0 to 40  C

o

Up to 95% 

3 years 

(1 

year for the lamp and the battery

)

 

GR-936

GR-937

GR-961/WP GR-962/WP

 GR-935

4.8V/3Ah

4.8V/3Ah

4.8V/1.5Ah

4 VA

IP 65

355 

x 145 x 73 mm 

840gr.

900gr.

1100gr.

1040gr.

980gr.

GENERAL

These  luminaires  are  used  in  places  where 
emergency luminaires are needed.
Each luminaire must be permanently connected 
to mains power supply

.

In  normal  operation  the  battery  is  charging  and 
the 2 yellow LED’s light in the screen

.

In  case  of  a  mains  power  supply failure  the  
luminary    will    light  the  lamp    automatically  in 
emergency  mode. 

 

When  the    mains    power   

supply    is    restored  the  device  turns  to  normal 
operation.

ΑΤΤΕΝΤΙΟΝ

!!!

1. Operations for installation, maintainance or 
testing must be done by authorized personel 
only

.

2. 

The device must be connected to the mains 

power supply thru a fuse dependent by the total 
amount of the line’s  power load

.

3. 

It is sugested to check every month the 

indication LED for battery charging, and by 
pushing the TEST button (see the paragraph 8 
on page 2), to check the emergency cirquit. The 
lamp should light as long as the TEST button is 
pressed

4. 

It is sugested to check every 6 months the 

minimum autononous duration by disconnecting 
the mains power supply

Count the time that  the 

lamp lights and in case of less time than the 
minimum autonomous duration the battery must 

. In the opposite condition contact the 

installer.

 

be replaced. If the measured time is considerably 
less than the minimum autonomous duration 

 In case of battery or lamp 

replacement, these must be replaced by parts of 
the same type

It is sugested  

hours of continuous operation The frequent 
failures of mains power supply reduces 
dramaticaly the lamp s life time

t i

 

in battery recycling points. Do not 

incinerate.

INSTALLATION

To  install  the  luminaire  follow  the  installation 
instructions on page 2.

NOTE:

 LED= Light Emitting Diode

LABELING EXPLANATION:
X: Self contained
0: Non Maintained
A: Including test device
*90: 90min duration 
180: 180min duration

contact the installer.

.

5. 

to replace the lamp every 

8000 

.  

.  

6. 

In case of inactive use for a period greater 

than 2 months, disconnect the battery by pulling 
out the battery’s connector.

 

7. 

I s not allowed to discard batteries in to 

common trash bins, they must be discarded 
only 

923962001_09_019

  11W (CFL) 

Page 2 of 2

923962001_09_019

1

  Remove the diffusor and the lamp. Place simultaneously 2 flat blade screwdrivers and pull up 

    gently the reflector.  

2

  

Install the included plastic cover in to the unused hole and install the base plastic (with the 

    included mounting screws and plugs).  

3

  

Instal the cable gland and pass the round cable thru. 

4

  Place the battery’s connector to the corresponding connector on the P.C.B

5

  Connect the mains as shown in figure 

1.

6

  

Install the

 

included tie (if needed) to fasten securely the power cables.

7

  Refit the reflector and fasten the two small screws (included).

8

  

Finaly place the lamp and the diffusor by using the 4 included screws (tightening torque 1.2Nm)

.  

INSTALLATION INSTRUCTIONS

Figure 

1

N

L

N

L

Mains connection

230V AC

Page 1 of 2

9  

Unfasten the mounting screws 

(

step

 

8

and remove the diffusor

.

 When the luminaire is supplied 

    by the mains

press on the marking for TEST as shown in the picture below.

 

Mount the diffusor by 

    using the 4 removed screws

.

    

TEST procedure with extra care

!!

1

3

2

4

7

6

8

Reviews: