Page 39
16.0 J-320/J-330/J-340 Circuit Diagram (60Hz)
This wiring diagram is used for all J-320, J-330, J-340 US/Canada 240 VAC
(60Hz) dedicated power models.
TRANSFORMER
SP
A
LIGHT
O
3
Optional CD Ozone
Circ.
Pump
L1
L2
PUMP
1
PUMP
2
LO
HI
HI
GRN
US / Canada 60Hz Power Connections
240 V
AC 60Hz, 1-Phase;
USE COPPER CONDUCT
ORS ONL
Y
, WIRE SIZE MUST
BE
APPROPRIA
TE PER NEC
AND/OR LOCAL
CODES
This device complies with Part
15 of the FCC rules. Operation is
subject to the following two
conditions:
1.
This device may not cause
harmful interference.
2.
This device must accept any
inteference received including
interference that may cause
undesired operation.
Optional Stereo on
J-340 Models Only
20A, 250 V
, SC-20
T
emp. Sensor
HI-Limit/Freeze Sensor
Flow Switch
Heater
5.5 kW
JP1
4
2
3
1
65
87
Logic Jumper Settings for all Domestic 60Hz Models:
JP1 1-2 ON = 30A
Logic
JP1 1-2 OFF = 50A
Logic
JP1 7-8 ON =
°
C T
emperature
Display
JP1 7-8 OFF =
°
F T
emperature