10
4.6 Programming the Circulation Pump Filtration Cycle (For models equipped with a circula-
tion pump)
Press and hold the
Jets pump 1
(
1
) and
Cooler
( ) button
at the
same time
for 3 seconds to access
the circulation pump programming. Continually press the
Warmer
( ) button to scroll up through the cycles
below. Then select a cycle and press the
Jets pump 1
(
1
) button to activate that cycle. Upon pressing the
jets pump 1 button the system will save your selection, exit the program menu and return to the main menu.
Note:
• 2014+ Any time the circulation pump runs outside of a programmed cycle (except for C0 and C6), that run time will
reduce the length of the next cycle.
• After 10 seconds the programming screen will revert back to the temperature if no buttons are pressed. You
cannot have more than one circulation pump cycle activated at a time.
Note:
The recommended factory default setting for the Select Series is 8 hours. This setting should not be
altered. Running the circulation pump less than the factory recommended time might result in issues with water
quality maintenance.
4.7 Programming the CLEARRAY® (Ultraviolet) Water Purification System (For models
equipped with a circulation pump)
A.
Programming the
CLEAR
RAY System (U) or Corona Discharge Ozone (O3)
Press and hold the
Jets pump 1
(
1
) and
Cooler
( ) button
at the
same time
for 3 seconds. Scroll pass
the circulation pump programming menus by pressing the Warmer button, Figure 1.
Press
Press
Press
Press
Press
Press
Press
Press
Press
1
Will select “O3”
option and exit
menu.
Will take you back
to “C0” option.
1. After the last cycle, “C6,” the LED screen will display “U” or “O3.” If the LED screen is displaying “U” then
pressing the Jets pump 1 will change the sanitizing system from “U” to “O3” and exit the programming
menu. If the LED screen is displaying “O3” then pressing the Jets pump 1 will change the sanitizing system
from “O3” to “U” and exit the programming menu. You will see one of the two configurations below:
A. C0, C1, C2, C3, C4, C5, C6, U, 365 (duration countdown timer)
B. C0, C1, C2, C3, C4, C5, C6, O3, =
Note:
For the O3 option the “=” disables the duration countdown timer.
0 hours of circulation per day
4 hours of circulation per day
8 hours of circulation per day (recommended factory default setting)
12 hours of circulation per day
16 hours of circulation per day
20 hours of circulation per day
24 hours of circulation per day
In extreme bitter cold weather,
32°F (0°C),
we recommend you program the circulation pump to run 24
hours.