![Jacuzzi JVS185S Owner'S Manual Download Page 20](http://html1.mh-extra.com/html/jacuzzi/jvs185s/jvs185s_owners-manual_3206622020.webp)
Page 20 of 32
IS3206VSP3J Rev-A
6.5.
Initial startup
After plumbing and wiring are complete, the variable speed drive must be configured prior to use. When power is applied
to the drive for the first time, the following informational screens are displayed.
Screen
Comments
1.
2.
Note:
Speeds can be selected at this time to temporarily run the pump, however, it is recommended that the drive
configuration and timers be set according to individual installation site requirements (see section 6.7 for more details). At
this point, pressing the MENU button will select the Configuration Menu.
6.6.
Configuration Menu
Buttons
Screen
Used
Comments
1.
< >
Press & hold < and > buttons for several seconds to
unlock Configuration Menu
2.
< >
Use > to enter Configuration Menu
3.
4.
+ -
Select language for all displayed messages
< >
Move to next menu item
5.
+ -
Use + to change clock setting
< >
Use > if clock is correct
6.
+ -
Adjust day/time setting
< >
Move to next selection, then to next menu item
7.
+ -
Select whether to display speed in rpm (Revolutions
per Minute) or % of full speed
< >
Move to next menu item
8.
+ -
Set maximum running speed of pump
< >
Move to next menu item
9.
+ -
Set minimum running speed of pump
< >
Move to next menu item
Thursday 1:27p
1725rpm 380 Watts
Timer 1 timer
will end at 11:45p
Configuration Menu
press > to enter
Set Day and Time
Thursday 1:27p
Speed Selection
rpm
Max allowed speed
3450 (600-3450rpm)
Min allowed speed
600 (600-3450rpm)
Configuration Menu
Locked
Display Language
English
Press +/- to change
or > view next item
Time: Th 1:27PM
+ change or > skip