Illumination
(Lx)
Source of light
Environment
A
(
Approx. Hours)
B (*)
C
(
Approx. Hours)
(
Approx. Minutes)
700
A fluorescent
lamp
Inside the office
-
18
69
3,000
30W
20cm
52
4
15
10,000
Sunlight
Cloudy
16
1.5
5
0
100,000
Fine
weather
. 5
2
5.
3
(
Dial transparency rate is 30%)
◆
Guidelines for c
harging time
The below table provides only general guidelines.
Condition A : Time required
for full charge
Condition B : Time required
for steady operation
Condition C : Time required for 1 day's charge
Even if the watch is not charged for the time specified in the column, the second hand may temporarily move at one-second
intervals. But it will soon resume moving at two-second intervals; therefore, charge the watch for more than the specified period.
(*) The values in this column
represent
the charging times required until the second hand moves constantly
at one-second
intervals
after the wa
tch starts operating w
ith the second hand moving at two-second intervals.
Display
ENGLISH
N →
1 →
2
Button A
Button B
Crown
Second hand
24 hour hand
Date
Stopwatch
minute hand
Minute hand
Hour hand
Stopwatch second hand
Crown position
N : normal
1 : 1st click
2 : 2nd click
Turn counterclockwise for
date change
Time setting
Restart
Stopwatch Start
Stop
Restart
Stopwatch hand
position adjustment
(clockwise)
release
Stopwatch Reset
Split
Split release
Stopwatch hand
position adjustment
(counterclockwise)
(Press more than 1 second)
Battery indicator
(Press more than 1 second)
(1) Pull the crown out to the 2nd click position when the second hand is at the 12 o'clock position.
- When the stopwatch is measuring, if the crown is pulled out to the 2nd click position, it will automatically reset the stopwatch hands to "0" position.
(2) Turn the crown to set the hour and minute hands.
Take a.m./p.m. into consideration when setting the hour and minute hands to the desired time.
- The 24 hour hand moves correspondingly with the hour hand.
- When setting the hour hand, check that the 24 hour hand is correctly set.
- When setting the minute hand, advance it 4 to 5 minutes ahead of the desired time and then turn it back to the exact time.
(3) Push the crown back to the normal position.
(1) Pull the crown out to the 1st click position.
(2) Turn the crown to set the date.
-Do not set the date between 9:00 p.m. and 1:00 a.m.
(3)Push the crown back to the normal position.
Tips : When the date changes during daytime, it happens when a.m./p.m. is wrongly set. Advance the hour hand by 12 hours.
This watch is a solar-powered watch containing a solar cell underneath the dial to convert any form of light into "electrical energy" and store
the power in a secondary battery. Unlike conventional quartz watches, this watch does not use a silver oxide battery, thus eliminating the
need for battery replacement.
■
Running time
Expected running time from full charge to stoppage will be around 4 months.
■
Over charge prevent function
If the secondary battery is charged more than predetermined voltage, over charge prevent function is operated to prevent the secondary
battery deterioration and breakage.
When the energy stored in the secondary battery is reduced to an extremely low level, the second hand starts moving at two-second
intervals instead of the normal one-second intervals. In that case, recharge the watch as soon as possible by exposing it to light.
Otherwise, the watch may stop operating in about 2 weeks.
Start
Stop
Reset
Button A
Button A
Button B
Button A
Button A
Button A
Button A
Button B
◆
Crown and button operation
Free
Button A
Stopwatch Start
Stop
Button B
Stopwatch Reset
Split
Split
Battery indicator
How to set date
◆
Features of the solar watch
◆
P
ower depletion warning function
◆
• The stopwatch can measure up to 29'59'' in one-second increasements.
• When the measurement reaches 30 minutes, the stopwatch automatically stops counting.
How to use stopwatch function
◆
■
Standard measurement
■
Accumulated elapsed time measurement
Position : 45 seconds
Position : 40 seconds
Battery level
High
Middle
If the stopwatch hands are not in the "0" position, follow the procedures below to set them.
(1) Pull the crown out to the 2nd click position.
- When the stopwatch is measuring, if the crown is pulled out to the 2nd click position, it will be automatically reset.
(2) Press the button A or B to set the stopwatch hands to the "0" position.
The movements of the stopwatch minute hand and the stopwatch second hand are interlocked. To set the stopwatch minute hand
to the "0" position, continue to move the stopwatch second hand until the stopwatch minute hand reaches the "0" position.
- The stopwatch hands move quickly if the button A or B is kept pressed.
(3) Push the crown back to the normal position.
Stopwatch hand position adjustment
◆
Guidelines for battery indicator
◆
• Press button B for more than 1 second. The remaining battery capacity is indicated.
• Status indication is 2 seconds. Then it returns automatically.
Position : 35 seconds
Button A
Button B
Button A
Button B
Button B
Measurement and release of split time
can be repeated by pressing the button B.
Start
Split
Split release
Reset
Stop
Low
How to charge and start the watch
◆
Restart and stop of the stopwatch can
be repeated by pressing the button A.
Start
Stop
Restart
Stop
Reset
■
Charging the watch
When you start the watch or when the energy remaining in the secondary battery is very low, charge it sufficiently by exposing the
watch to light.
(1) Expose the watch to sunlight or strong artificial light (of more than 1,000 Lx). When the watch has stopped operating, the second
hand will start moving at two-second intervals.
- The second hand immediately starts moving at two-second intervals, but the energy stored in the secondary battery is not yet sufficient. If the watch is turned away from the light,
it may stop operating. It is not necessary to charge the watch fully. It is important, however, to charge the watch sufficiently, especially in the case of initial charging.
(2) Keep the watch exposed to the light until the second hand moves at one-second intervals.
(3) When the watch is charged after it has completely stopped, set the date and time before wearing the watch.
■
Caution
When charging the watch, do not place it too close to fluorescent lamp or other light sources as the watch temperature will become
extremely high, causing damage to the parts inside the watch.
■
To prevent energy depletion
• Avoid covering the watch face with your clothing while wearing it.
• When the watch is not in use, leave it in a brightly lit place for as long as possible.
Make sure that the watch temperature does not exceed 50℃.
■
Split time measurement
■
Measurement of two competitors
Display
Power reserve
90 days or more
30 -90 days
30 days or less
Start
Reset
Finish time of
1st competitor
2nd competitor
finishes
Finish time of
2nd competitor
• The stopwatch second hand is capable of timing 30 minutes. (60 seconds x 30 times)
• The stopwatch minute hand is capable of timing 30 minutes.
• Before using the stopwatch, be sure to check that the crown is set at the normal position and that the stopwatch hands are reset
to the "0" position.
-If the stopwatch hands do not return to the "0" position when the stopwatch is reset to "0", follow the procedure in "Stopwatch hand position adjustment".
Button B
Button A
Button B
Button B
Button A
JL.DA
R42
V
INSTRUCTION MANUAL
◆
How to set time
Crown