background image

Illumination

(Lx)

Source of light

Environment

A

(

Approx. Hours)

B (*)

C

(

Approx. Hours)

(

Approx. Minutes)

700

A fluorescent

 

lamp

Inside the office

18

 69

3,000

30W

 

20cm

52

4

15

10,000

Sunlight

Cloudy

16

1.5

5

0

100,000

Fine

 weather

     . 5 

  2   

 5.

3

(

Dial transparency rate is 30%)

Guidelines for c

harging time

The below table provides only general guidelines.

Condition A  :  Time required 

for full charge

Condition B  :  Time required

 

for steady operation

Condition C  :  Time required for 1 day's charge

Even if the watch is not charged for the time specified in the column, the second hand may temporarily move at one-second  

intervals. But it will soon resume moving at two-second intervals; therefore, charge the watch for more than the specified period.

(*) The values in this column

 

represent

 the charging times required until the second hand moves constantly

 

at one-second 

intervals

 

after the wa

tch starts operating w

ith the second hand moving at two-second intervals.

 

 

 

Display

ENGLISH

N →

 

1 →

 

2

 

Button A

 

Button B

 

Crown

Second hand

 

24 hour hand

Date

Stopwatch 

minute hand

 

Minute hand

 

Hour hand 

 

Stopwatch second hand

Crown position  

N : normal

1 : 1st  click

2 : 2nd  click

Turn counterclockwise for 

date change  

Time setting

 

Restart  

Stopwatch Start  

                   Stop  

                   Restart  

Stopwatch hand

 

 

position adjustment

 

(clockwise)

 

 

release  

Stopwatch  Reset   

                    Split  

                    Split  release  

Stopwatch hand

 

position adjustment

 

(counterclockwise)

  

 

(Press more than 1 second)

   Battery indicator  

(Press more than 1 second)

 

(1) Pull the crown out to the 2nd click position when the second hand is at the 12 o'clock position.

        - When the stopwatch is measuring, if the crown is pulled out to the 2nd click position, it will automatically reset the stopwatch hands to "0" position.

(2) Turn the crown to set the hour and minute hands.

      Take a.m./p.m. into consideration when setting the hour and minute hands to the desired time.

        - The 24 hour hand moves correspondingly with the hour hand.

        - When setting the hour hand, check that the 24 hour hand is correctly set.

        - When setting the minute hand, advance it 4 to 5 minutes ahead of the desired time and then turn it back to the exact time.

(3) Push the crown back to the normal position.

(1) Pull the crown out to the 1st click position.

(2) Turn the crown to set the date.

      

-Do not set the date between 9:00 p.m. and 1:00 a.m.

(3)Push the crown back to the normal position.

Tips : When the date changes during daytime, it happens when a.m./p.m. is wrongly set. Advance the hour hand by 12 hours.

This watch is a solar-powered watch containing a solar cell underneath the dial to convert any form of light into "electrical energy" and store 
the power in a secondary battery. Unlike conventional quartz watches, this watch does not use a silver oxide battery, thus eliminating the 
need for battery replacement.

■ 

Running time

Expected running time from full charge to stoppage will be around 4 months.

■ 

Over charge prevent function

If the secondary battery is charged more than predetermined voltage, over charge prevent function is operated to prevent the secondary 
battery deterioration and breakage.

When the energy stored in the secondary battery is reduced to an extremely low level, the second hand starts moving at two-second 
intervals instead of the normal one-second intervals. In that case, recharge the watch as soon as possible by exposing it to light. 
Otherwise, the watch may stop operating in about 2 weeks. 

Start

 

Stop

 

Reset

 

Button A  

Button A  

Button B  

Button A 

Button A 

Button A 

Button A 

Button B 

 

 

Crown and button operation

 

Free  

Button A  

Stopwatch Start  

                   Stop  

                  

Button B

 

Stopwatch  Reset 

                   Split  

                   Split  

   Battery indicator

   

 

How to set date 

 

Features of the solar watch 

 

P

ower depletion warning function  

 

• The stopwatch can measure up to 29'59'' in one-second increasements. 

• When the measurement reaches 30 minutes, the stopwatch automatically stops counting.  

How to use stopwatch function 

 

Standard measurement

Accumulated elapsed time measurement

Position : 45 seconds

Position : 40 seconds

Battery level

 

 

High  

Middle  

If the stopwatch hands are not in the "0" position, follow the procedures below to set them.

 

(1) Pull the crown out to the 2nd click position. 

          

- When the stopwatch is measuring, if the crown is pulled out to the 2nd click position, it will be automatically reset. 

(2) Press the button A or B to set the stopwatch hands to the "0" position. 

     The movements of the stopwatch minute hand and the stopwatch second hand are interlocked. To set the stopwatch minute hand 

     to the "0" position, continue to move the stopwatch second hand until the stopwatch minute hand reaches the "0" position. 

         - The stopwatch hands move quickly if the button A or B is kept pressed. 

(3) Push the crown back to the normal position. 

Stopwatch hand position adjustment 

 

Guidelines for battery indicator 

 

• Press button B for more than 1 second. The remaining battery capacity is indicated. 

• Status indication is 2 seconds. Then it returns automatically. 

Position : 35 seconds

Button A

Button B

Button A

Button B

Button B

Measurement and release of split time 

can be repeated by pressing the button B. 

Start

 

Split

 

Split release

 

 

 

 

 

 

Reset

 

Stop

 

 

Low  

How to charge and start the watch 

 

Restart and stop of the stopwatch can 

be repeated by pressing the button A. 

 

Start 

Stop 

Restart 

Stop 

Reset 

 

 Charging the watch 

     When you start the watch or when the energy remaining in the secondary battery is very low, charge it sufficiently by exposing the 

     watch to light.

     (1) Expose the watch to sunlight or strong artificial light (of more than 1,000 Lx). When the watch has stopped operating, the second     

          hand will start moving at two-second intervals.  

 

             - The second hand immediately starts moving at two-second intervals, but the energy stored in the secondary battery is not yet sufficient. If the watch is turned away from the light,

           

   it may stop operating. It is not necessary to charge the watch fully. It is important, however, to charge the watch sufficiently, especially in the case of initial charging. 

     (2) Keep the watch exposed to the light until the second hand moves at one-second intervals. 

      (3) When the watch is charged after it has completely stopped, set the date and time before wearing the watch. 

 Caution 

     When charging the watch, do not place it too close to fluorescent lamp or other light sources as the watch temperature will become     

     extremely high, causing damage to the parts inside the watch. 

 To prevent energy depletion 

     • Avoid covering the watch face with your clothing while wearing it. 

     • When the watch is not in use, leave it in a brightly lit place for as long as possible. 

       Make sure that the watch temperature does not exceed 50℃. 

Split time measurement

Measurement of two competitors

  Display  

Power reserve

 

 

   

90 days or more    

 

30 -90  days  

 

30 days or less  

Start  

 

 

 

 

 

Reset  

Finish time of 

1st competitor 

2nd competitor 

finishes  

Finish time of 

2nd competitor 

• The stopwatch second hand is capable of timing 30 minutes. (60 seconds x 30 times) 

• The stopwatch minute hand is capable of timing 30 minutes. 

• Before using the stopwatch, be sure to check that the crown is set at the normal position and that the stopwatch hands are reset 

  to the "0" position. 

       

-If the stopwatch hands do not return to the "0" position when the stopwatch is reset to "0", follow the procedure in "Stopwatch hand position adjustment". 

Button B

Button A

Button B

Button B

Button A

JL.DA

 R42

V

INSTRUCTION MANUAL

 

 

 

How to set time 

Crown

 

 

Reviews: