ELECTRICAL
4181384 First Edition
4-53
4
Start Circuit
Symptom: Starter motor solenoid does not engage.
Symptom: Fuel shutoff solenoid pull-in coil does not energize.
Probable Cause
Remedy
Park brake switch in the released position.
Place the park brake switch in the locked position.
Neutral switch is in the pedal engaged
position.
Move drive pedals to the neutral position.
Seat switch is in the off position.
Operator must be in the seat.
Mow switch is in the mow position.
Place the mow switch in the off position.
Open 15A fuse F6.
Test fuse. (See “Fuse Test” on page 4-61.)
Faulty seat switch.
Test switch. (See “Seat Switch Test” on page 4-65.)
Faulty park brake switch.
Test switch. (See “Park Brake Switch Test” on page 4-67.)
Faulty neutral switch.
Test switch. (See “Traction Pedal Neutral Switch Test” on page 4-65.)
Faulty key switch.
Test switch. (See “Key Switch Test” on page 4-63.)
Faulty Start relay.
Test relay. (See “Relay Tests” on page 4-62.)
Faulty 5V power supply circuit.
With the key switch in the run position, measure voltage between control module 5V
power supply terminal and ground. Voltage must be approximately 5 VDC.
Faulty 5V park brake switch input circuit.
With the key switch in the run position, measure voltage between control module 5V park
brake input terminal and ground. Voltage must be approximately 5 VDC.
Faulty 5V seat switch input circuit.
With the key switch in the run position, measure voltage between control module 5V seat
input terminal and ground. Voltage must be approximately 5 VDC.
Faulty 12V start relay output circuit.
With the key switch in the run position, measure voltage between control module 12V
start relay output terminal and ground.
With the key switch in the run position, measure voltage between start relay terminal 1
and ground.
Voltage must be approximately 12 VDC.
Faulty start relay ground circuit.
Measure continuity between start relay terminal 2 and ground. Continuity must be
indicated.
Faulty key switch start circuit.
With the key switch in the start position, measure voltage between start relay terminal 5
and ground. Voltage must be approximately 12 VDC.
Faulty start relay output circuit.
With the key switch in the start position, measure voltage between the starter motor
solenoid terminal and ground. Voltage must be approximately 12 VDC.
Probable Cause
Remedy
Faulty pull-in coil.
Test fuel shutoff solenoid. (See “Fuel Shutoff Solenoid Test” on page 4-69.)
Faulty pull-in coil circuit.
With the key switch in the start position, measure voltage at fuel shutoff solenoid wht/blu
wire terminal. Voltage must be approximately 12 VDC.
Summary of Contents for AR3
Page 1: ...AR 3 TR 3 Trim Mowers Technical Repair Manual AR30001 AR30002 TR30001 TR30002...
Page 3: ......
Page 7: ......
Page 9: ...1 2 4181384 First Edition SAFETY 1 Page Intentionally Blank...
Page 19: ...1 12 4181384 First Edition SAFETY 1...
Page 33: ...2 14 4181384 First Edition SPECIFICATIONS AND GENERAL INFORMATION 2 Page Intentionally Blank...
Page 73: ...4 16 4181384 First Edition ELECTRICAL 4 Page Intentionally Blank...
Page 85: ...4 28 4181384 First Edition ELECTRICAL 4 Page Intentionally Blank...
Page 147: ...4 90 4181384 First Edition ELECTRICAL 4 Page Intentionally Blank...
Page 200: ...HYDRAULICS 4181384 First Edition 6 9 6 Page Intentionally Blank...
Page 249: ...6 58 4181384 First Edition HYDRAULICS 6 Page Intentionally Blank...
Page 251: ...7 2 4181384 First Edition STEERING 7 Page Intentionally Blank...
Page 264: ...STEERING 4181384 First Edition 7 15 7 Page Intentionally Blank...
Page 265: ...7 16 4181384 First Edition STEERING 7...
Page 311: ...8 46 4181384 First Edition CUTTING UNITS 8 Page Intentionally Blank...
Page 331: ...9 20 4181384 First Edition ACCESSORIES AND MISCELLANEOUS REPAIR 9 Page Intentionally Blank...
Page 340: ......
Page 342: ......