22
07610-004-33-05-E
On 3-Phase machines only, correct pump motor rotation must be verified before
the machine is operated. Failure to do so can result in damage to the machine and
components.
1.
Follow the "Power Up" section.
2. Remove the front panel of the machine.
3.
Locate the wash pump motor and identify the arrow decal which shows the correct
motor rotation (if no decal is present, correct rotation is toward back of machine).
4.
Push the Delime Button on the display.
5. Observe rotation of the motor and quickly push the Delime Button again.
6. If rotation is incorrect, disconnect electrical power and reverse the L1 and L2
connections at terminal block shown in the previous section.
The machine should be located with an adequate exhaust hood or ventilation system with
provisions for venting. This is essential to permit efficient removal of the condensation
exhaust. Ensure the exhaust system is acceptable in accordance with applicable codes
and standards.
Any damage caused by steam and/or moisture due to improper ventilation
is NOT covered under the warranty.
Dishmachine ventilation requirements:
• Load End: 200 CFM
• Unload End: 200 CFM
The exhaust system must be sized to handle this volume for the machine to operate
properly.
The thermostats on this machine have been set at the factory for the wash tank and should
only be adjusted by an authorized service agent.
There are two Table Limit Switch options available. See the "Miscellaneous/Options" page for
ordering information. Click on the instruction icons below for install guides.
Striker
Switch
Whisker
Switch
INSTALLATION
INSTRUCTIONS
THERMOSTATS
VENTILATION
NOTICE
TABLE LIMIT
SWITCH OPTION
MOTOR
ROTATION
i
CAUTION!
On
3-Phase machines
only, correct pump
motor rotation
must be verified
before operation!
!
CAUTION