19
07610-004-43-79-Q
The manufacturer highly recommends that any maintenance and repairs not specifically
discussed in this manual only be performed by qualified service personnel. Performing
maintenance on the machine may void a warranty.
By following operating and cleaning instructions in this manual, users should get
the most efficient results from the machine. As a reminder, here are some steps to
ensure the machine is used properly:
1. Ensure water temperatures match those listed on machine data plate (on front-
left of machine).
2. Remove as much soil as possible from ware before loading into racks.
3. Ensure strainers are in place, laying flat in tub, and free of soil and debris before
operating machine. To clean strainers, wipe out with a rag and rinse under a
faucet. For stubborn debris, a toothpick can be used. Do not beat strainers on
waste cans; once bent, they will not work properly.
4.
Ensure all wash and rinse arms are secure in machine before operating.
PREVENTATIVE MAINTENANCE
MAINTENANCE
PREVENTATIVE
MAINTENANCE
i
XXXXXXXXX
ATTENSION: SE CONNECTER A UN MINIMUM D’ALIMENTATION 30 AMPERES
DELAI FUSIBLE DE TYPE NON-TEMPS OU LA PROTECTION CONTRE LES SURINTENSITES.
NOTE: WASH AND RINSE HEATER DO NOT OPERATE
AT THE SAME TIME. ELECTRICAL LOADS BASED ON WASH
MOTOR AND RINSE HEATER (HIGHEST AMP DRAW)
CAUTION: IF THIS MACHINE IS CONNECTED TO A CIRCUIT PROTECTED BY FUSES,
U S E
O N L Y
3 0 A
N O N - T I M E
D E L A Y
F U S E
O R
O V E R C U R R E N T
PROTECTION.
SERIAL NO.:
60Hz 1 PH 2 WIRE
5.0 A
230 VOLT
1 HP
MODEL:
DISHSTAR HT-E
Made in the USA
Jackson WWS , Inc
6209 N US HWY 25E
Gray, KY 40734
(606) 523-9795
09905-004-42-87D
155°F
180°F
110°F
80 SEC
5.0 A
17.4 A
4 KW
15.9 A
3.3 KW
26.7 A
24.7 A
WASH MOTOR
RINSE HEATER
TOTAL LOAD
OPERATING PARAMETERS
MINIMUM WASH TEMP
MINIMUM RINSE TEMP
MIN. INCOMING WATER TEMP
WASH CYCLE TIME
RINSE CYCLE TIME
WATER FLOW PRESSURE
208 VOLT
9 SEC
1 HP
10 PSI
WASH HEATER
19.7 A
5 KW
21.7 A
4.1 KW
MINIMUM CIRCUIT AMPACITY
MAXIMUM OVERCURRENT PROTECTION
@208 VOLTS: 26.0 AMPS
@230 VOLTS: 28.0 AMPS
@208 VOLTS: 30 AMPS
@230 VOLTS: 30 AMPS
4000897
Conforms to UL Std 921
Conforms to CSA
Std C22.2 No.168
Intertek
4000897
Conforms to NSF Std 3
CAUTION!
Do NOT beat
strainers to remove
soil and debris!
!
CAUTION