background image

Comfort System T-32-P Universal

Thermostat

Operation Manual

TM

O

TM

Summary of Contents for Comfort System T-32-P

Page 1: ...Comfort System T 32 P Universal Thermostat Operation Manual TM O TM...

Page 2: ...to it is operating to their respective specifications and in a safe manner Due to ongoing product improvements Jackson Systems reserves the right to change the specifications of the T 32 P thermostat...

Page 3: ...ith a call for heating or cooling The HVAC system fan will run continuously FAN KEY MODE O RIDE PROG FAN Cool Heat Setting the clock PROG PROG PROG PROG The T 32 P has a real time clock that is used f...

Page 4: ...he key again and the minutes will flash Use the up or down key to set the minutes for program to start 1 1 1 UP DOWN KEYS 1 1 1 1 1 1 Press the key again and or will be displayed along with the temper...

Page 5: ...again and the word will flash briefly to confirm the copy process Normal programming steps will resume showing the next day to be programmed PROG Heat Cool PROG PROG PROG COPY Option 1 Copy Program P...

Page 6: ...g with the word Press the up or down key to change the temperature To return to the programmed schedule press the key until the word is no longer displayed Your can review the set temperatures at any...

Page 7: ...rrect day of the week Press the again to exit the clock and day of week program PROG KEY UP DOWN KEYS Start Programming 2 daily events Start Stop Start Stop The commercial programmable mode provides 2...

Page 8: ...Wait 3 second and the next mode or will be displayed and can be changed When the T 32 P will exit the override program The word or will flash confirming the override event The HVAC installer will hav...

Page 9: ...Start Time Heating Cooling Heating Cooling Start 6 00 AM 70 75 62 83 Stop 6 00 PM 62 83 62 83 Non programmable Mode MODE O RIDE PROG FAN Cool Heat PROG KEY UP DOWN KEYS Day MODE Selection MODE Heat C...

Page 10: ...on the display after adjusting the heating temperature wait without touching a key for 3 seconds The T 32 P will change to show and Press the up or down key to change the temperature setting for cooli...

Page 11: ...s key is used to set the clock and program daily events Program This key is used to set the clock and switch between and modes HOLD FAN Key Fan ON Auto Fan Advanced Fan Function ON Auto Heating Call H...

Page 12: ...e cooling call takes place LCD Symbols TIMER Day Clock Set or room temperature Outside air temperature Program hold active Override timer activated Keyboard or control limit is locked Modbus communica...

Page 13: ...ress MODE key to set system to Cool Make sure the temperature is set lower than the inside temperature Check circuit breaker and reset if necessary Make sure power switch at HVAC system is on Make sur...